Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93, Standard Test Method for Flash Point by Pensky-Martens Closed Cup
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point:
> 109.5 - < 110.5 °C
Atm. press.:
101.3 hPa
Conclusions:
The flash point of 6 -chlorohexan-1-ol determined by Pensky-Martens closed cup method is 110.5 oC
Executive summary:

The flash point of 6 -chlorohexan-1-ol determined by Pensky-Martens closed cup method is 110.5 oC

Description of key information

The flash point of 6 -chlorohexan-1-ol determined by Pensky-Martens closed cup method is 110.5 C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
110.5 °C

Additional information