Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 Mar - 22 Sep 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Version / remarks:
adopted in 1981
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium für Umwelt, Energie, Landwirtschaft und Verbraucherschutz,Wiesbaden, Germany

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction products of trimethylolpropane triglycidyl ether and acrylic acid
EC Number:
603-303-1
Cas Number:
128819-84-1
Molecular formula:
C18 H30 O9, C21 H35 Cl O10, C24 H38 O12 and C27 H43 Cl O13 (mainly)
IUPAC Name:
Reaction products of trimethylolpropane triglycidyl ether and acrylic acid
Specific details on test material used for the study:
Storage conditions: ambient temperature (< 40 °C), keep container tightly closed, protected from sunlight

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Remarks:
The exothermic decomposition energy was ca. -200 J/g.
Operating temperature
Operating temp.:
ca. 25 - <= 300 °C

Any other information on results incl. tables

Results
Thermal stability
In the temperature range of 180 – 260 °C an exothermic effect was observed, with decomposition energy equal to -200 J/g. At 300 °C the test was terminated.

Table 1 – DSC measurement results

Sample weight [mg]

Start [°C]

Energy [J/g]

10.12

180 (exothermic)

-200

Applicant's summary and conclusion