Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30. May 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test over 100 mm length
Burning time:
7 min
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The combustion along 200 mm took 7 minutes. This leads to a combustion rate of 0.476 mm/s.
As the combustion with flame of the test item propagated more than 4 minutes along 200 mm of the string, the test item 2-Lauroyloxyethyltrimethylammonium Chloride should be considered as not highly flammable (for EU regulations) and non-flammable solid (for UN regulations), respectively.

Description of key information

The combustion along 200 mm took 7 minutes. This leads to a combustion rate of 0.476 mm/s.

As the combustion with flame of the test item propagated more than 4 minutes along 200 mm of the string, the test item 2-Lauroyloxyethyltrimethylammonium Chloride should be considered as not highly flammable (for EU regulations) and non-flammable solid (for UN regulations), respectively.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification