Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.08.15 - 07.01.16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point/Boiling Range)
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Decomposition:
yes
Decomp. temp.:
>= 110 °C
Remarks on result:
other:
Remarks:
The test item melted under decomposition. Therefore the test item had no boiling point at atmospheric conditions.
Conclusions:
The test item melted under decomposition within a range of 110 - 155 °C under atmospheric conditions. Therefore the test item had no boiling point at atmospheric conditions.
Executive summary:

A study was conducted according to OECD test guideline 103 and Regulation (EC) No 440/2008 method A.2 to determine the boiling point of the test item using differential scanning calorimetry. The test item and the reference are heated up from the starting temperature to the final temperature at a constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for the test item and as empty reference crucible. The quantity of heat absorbed or released is measured and recorded. The test item melted under decomposition within a range of 110 - 155 °C under atmospheric conditions. Therefore the test item had no boiling point at atmospheric conditions.

Description of key information

A study was conducted according to OECD test guideline 103 and Regulation (EC) No 440/2008 method A.2 to determine the boiling point of the test item using differential scanning calorimetry. The test item and the reference are heated up from the starting temperature to the final temperature at a constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for the test item and as empty reference crucible. The quantity of heat absorbed or released is measured and recorded. The test item melted under decomposition within a range of 110 - 155 °C under atmospheric conditions. Therefore the test item had no boiling point at atmospheric conditions.

Key value for chemical safety assessment