Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
GLP compliance:
yes
Type of method:
OECD harmonised ring method

Test material

Constituent 1
Reference substance name:
Reaction products of diazotized 4-amino-6-[(4-aminophenyl)diazenyl]-3-[(4-aminophenyl)diazenyl]-5-hydroxynaphthalene-2,7-disulfonic acid, coupled with benzene-1,3-diamine, sodium salts
EC Number:
812-037-7
Cas Number:
1793011-72-9
Molecular formula:
Unknown for all components
IUPAC Name:
Reaction products of diazotized 4-amino-6-[(4-aminophenyl)diazenyl]-3-[(4-aminophenyl)diazenyl]-5-hydroxynaphthalene-2,7-disulfonic acid, coupled with benzene-1,3-diamine, sodium salts
Test material form:
solid

Results and discussion

Surface tension
Surface tension:
74.6 mN/m
Temp.:
20 °C
Conc.:
1 g/L

Any other information on results incl. tables

Individual values ranged between 71.5 to 72.2 mN/m for the 6 measurements made. Non-corrected mean = 71.7 mN/m

Applicant's summary and conclusion

Conclusions:
The surface tension of a test solution at a concentration of 1 g/L in water and at 20°C was 74.6 mN/m. According to this, the test item is considered not to be surface active.