Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
For justification of read-across please refer to the read-across report attached to IUCLID section 13.
Reason / purpose for cross-reference:
read-across source
Key result
Decomposition:
yes
Decomp. temp.:
> 150 °C
Conclusions:
The test item started to melt at 90°C followed by decomposition. No boiling was observed.
Executive summary:

The boiling point of the test substance was determined via Differential Scanning Calorimetry (DSC) and capillary tube in a metal block according to OECD 103.

For DSC, the test item was heated continously until the final temperature was reached while measureing and recording the quantity of absorbed and released heat.

For the capillary tube method, the test item was filled to a height of approx. 5 mm into the test tube and heated to the maximum temperature (410°C), while any changes of the substance are observed and recorded.

Considering the results from the thermal stability, DSC and capillary tube method, the test substance started to melt at 90°C followed by decomposition. Therefore no boiling point or range could be determined.

This information is used in a read-across approach in the assessment of the target substance.

For justification of read-across please refer to the attached read-across report (see IUCLID section 13).

Description of key information

The boiling point of the test substance was determined via Differential Scanning Calorimetry (DSC) and capillary tube in a metal block according to OECD 103.

Considering the results from the thermal stability (ambiguous onset), DSC and capillary tube method, the test substance started to melt at 90°C followed by decomposition. Therefore, no boiling point or range could be determined.

This information is used in a read-across approach in the assessment of the target substance.

For justification of read-across please refer to the attached read-across report (see IUCLID section 13).

Key value for chemical safety assessment