Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
> 300 °C
Atm. press.:
101.2 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test item 1,2-Ethanediamine, N-(2-aminoethyl)-, reaction products with glycidyl tolyl ether flash point has been determined using closed cup method. Flash point is greater than 300 °C.
Executive summary:

The test item 1,2-Ethanediamine, N-(2-aminoethyl)-, reaction products with glycidyl tolyl ether flash point has been determined using closed cup method. Flash point is greater than  300 °C.

Description of key information

The test item 1,2-Ethanediamine, N-(2-aminoethyl)-, reaction products with glycidyl tolyl ether flash point has been determined using closed cup method. Flash point is greater than  300 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
300 °C

Additional information