Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05-2017
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
2-{2-[(2-ethylhexyl)oxy]ethoxy}ethyl prop-2-enoate
Cas Number:
117646-83-0
Molecular formula:
C15H28O4
IUPAC Name:
2-{2-[(2-ethylhexyl)oxy]ethoxy}ethyl prop-2-enoate
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
110 °C
Atm. press.:
760 mm Hg

Applicant's summary and conclusion

Conclusions:
Flash point testing was done in a Cleveland Open Cup Flash point tester. The flash point test was performed Miramer
M1086 and the result of the test is 110°C at 760 mm Hg.
Executive summary:

Flash point testing was done in a Cleveland Open Cup Flash point tester. The flash point test was performed Miramer

M1086  and the result of the test is 110°C at 760 mm Hg.