Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11.11.2008 - 22.01.2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
215.4 µm
St. dev.:
1.8
Percentile:
D10
Mean:
28.8 µm
St. dev.:
0.03
Percentile:
D90
Mean:
862.4 µm
St. dev.:
16.6

The median particle size D50 (50 % of particle volume with lower particle diameter) from the two series are:

1st test series: D50 = 213.53 µm

2nd test series: D50 = 217.19 µm

The average of the median particle size D50 was 215.4 µm.

The particle size D10 (10 % of particle volume with lower particle diameter) from the two series are:

1st test series: D10 = 28.84 µm

2nd test series: D10 = 28.79 µm

The average of the particle size D10 was 28.8 µm.

The particle size D90 (90 % of particle volume with lower particle diameter) from the two test series are:

1st test series: D90 = 845.79 µm

2nd test series: D90 = 879.00 µm

The average of the particle size D90 was 862.4 µm.

Conclusions:
The test item has a median particle size D50 = 215.4 µm.
Executive summary:

A study was conducted according to OECD TG 110, OPPTS 830.7520 and ISO 13320 to determine the particle size distribution of the test item. The particle size distribution was determined using laser diffraction. Two test series were performed with the test item. The test item has a median particle size D50 = 215.4 µm, which was determined by laser diffraction measurement.

Description of key information

The test has a median particle size D50 = 215.4 µm.

Additional information

A study was conducted according to OECD TG 110, OPPTS 830.7520 and ISO 13320 to determine the particle size distribution of the test item. The particle size distribution was determined using laser diffraction. Two test series were performed with the test item. The test has a median particle size D50 = 215.4 µm, which was determined by laser diffraction measurement.