Administrative data

First-aid measures

General information: Take care of personal protection for the first aider.
After inhalation: In case of unconsciousness place patient stably in side position for transportation. Take affected persons into fresh air and keep quiet.
After skin contact: Immediately wash with water and soap and rinse thoroughly. Immediately remove contaminated clothing.
After eye contact: Rinse opened eye for several minutes under running water.
After swallowing: If symptoms persist consult doctor.

Fire-fighting measures

Suitable extinguishing agents: CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
For safety reasons unsuitable extinguishing agents: Water with full jet
Special hazards arising from the substance or mixture: Under certain fire conditions, traces of other toxic gases cannot be excluded. Hydrocarbons, carbondioxide and -monoxid.

Advice for firefighters:
Protective equipment: Do not inhale explosion gases or combustion gases.
Additional information: Cool endangered receptacles with water spray. Self-protection first!

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Keep away from ignition sources. In case of further temperature should be cooled with waterspray from a safe distance. Wear breathing apparatus with filter A during decomposition of materials. Wear protective equipment. Keep unprotected persons away.

Environmental precautions: Do not allow to enter sewers/ surface or ground water.

Methods and material for containment and cleaning up: Dispose contaminated material as waste according to disposal considerations. Ensure adequate ventilation. Large quantities should be diluted with suitable desensitation agent to a concentration below 10 % before disposal. Soak up with absorbant material (e. g. Vermiculit) and dispose of in accordance with government regulations.

Handling and storage

Precautions for safe handling:
Keep away from heat and direct sunlight.
Open and handle receptacle with care.
Prevent formation of aerosols.
Wear suitable respiratory protective device when decanting larger quantities without extractor facilities.
Do not refill residue into storage receptacles.
Restrict the quantity stored at the work place.
Before break and at the end of work hands should be thoroughly washed.
Only use tools made of suitable materials (e. g. polyethylene or stainless steel).
Keep away from dirt, rust, chemicals in particular concentrated acids, alkalis and accelerators (e. g. heavymetal
compounds and amines).
Oxidizing because of releasing oxygene.
While using do not eat, drink or smoke.
Do not generate flames or sparks.
Keep product and emptied container away from heat and sources of ignition.
Avoid shock and friction.
Take precautionary measures against static discharges.
Do not smoke.

Information about fire - and explosion protection:
Protect from heat.
Protect against electrostatic charges.
Prevent impact and friction.
Use explosion-proof apparatus / fittings and spark-proof tools.
Fumes can combine with air to form an explosive mixture.
Wear shoes with conductive soles.
Formation of flammable or explosive gas/air-mixtures is possible.
Avoid open flames, sparks, direct sunlight and other sources of ignition.
Keep ignition sources away - Do not smoke.

Conditions for safe storage, including any incompatibilities
· Storage: Pay attention to the special requirements of your local autorithies for storing dangerous goods.
·Requirements to be met by storerooms and receptacles: Store only in the original receptacle. Prevent any seepage into the ground. Use only receptacles specifically permitted for this substance/product.
· Information about storage in one common storage facility Do not store or park organic peroxide together with heavy metal compounds and amines. Store away from foodstuffs, drinks and feeding stuffs.
· Further information about storage conditions: Keep container tightly sealed. Protect from heat and direct sunlight. Protect from contamination.
· Recommended storage temperature (To maintain quality): max.: -15 °C
· Control temperature: -10 °C
· Emergency temperature: 0 °C
· Storage class: 5.2





Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3115
Shipping information
Proper shipping name and description:
3115 ORGANIC PEROXIDE TYPE D, LIQUID, TEMPERATURE CONTROLLED (CUMYLPEROXYNEODECANOATE)
Labels:
5.2
Special provisions / remarks
Special provisions:
· Limited quantities (LQ) 0
· Transport category 1
· Tunnel restriction code D
Remarks:
· Special precautions for user: Warning: Organic peroxides.
· Control temperature: -10 °C
· Emergency temperature: 0 °C
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3115
Shipping information
Proper shipping name and description:
ORGANIC PEROXIDE TYPE D, LIQUID, TEMPERATURE CONTROLLED (CUMYLPEROXYNEODECANOATE)
Labels:
5.2
Special provisions / remarks
Remarks:
Special precautions for user: Warning: Organic peroxides.
· Special precautions for user: Warning: Organic peroxides.
· Control temperature: -10 °C
· Emergency temperature: 0 °C

Air transport (UN RTDG/ICAO/IATA)

UN number:
no admission
Shippingopen allclose all
Special provisions / remarks
Remarks:
no admission
SpecialProvisionsopen allclose all

Exposure controls / personal protection

General protective and hygienic measures:
· The usual precautionary measures are to be adhered to when handling chemicals.
· Keep away from foodstuffs, beverages and feed.
· Immediately remove all soiled and contaminated clothing
· Wash hands before breaks and at the end of work.
· Store protective clothing separately.
· Avoid close or long term contact with the skin.
· Avoid contact with the eyes and skin.
· Do not eat, drink, smoke or sniff while working.
· Use skin protection cream for skin protection.
· Be sure to clean skin thoroughly after work and before breaks.

Respiratory protection:
· Not necessary if room is well-ventilated.
· Use suitable respiratory device when it exceed exposure limit and when insufficiently ventilated.
· Filter A2

Protection of hands:
· Protection of hands: Only use chemical-protective gloves with CE-labelling of category III.
· Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation


Material of gloves:
· The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.
· Butyl rubber, BR
· Fluorocarbon rubber (Viton)
· Nitrile rubber, NBR
· Neoprene

Penetration time of glove material:
· The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye protection:
· Tightly sealed goggles

Body protection:
· Protective work clothing

Stability and reactivity

Chemical stability:
· Thermal decomposition / conditions to be avoided: SADT (Self Accelerating Decomposition Temperature) is the lowest temperature at which self accelerating decomposition may occur with substance in the packaging as used in transport. A dangerous selfaccelerating decomposition reaction and, under certain circumstances, explosion or fire can be cause decomposition at and above the temperature. Contact with incompatible substances can cause decomposition at or below the SADT. No decomposition if used and stored according to specifications. To avoid thermal decomposition do not overheat.

Possibility of hazardous reactions: Self-accelerating decomposition at SADT.

Incompatible materials: Rapid decomposition by dirt, rust, chemicals in particular concentrated acids, alkalis and accelerators (e. g. heavy-metal compounds and amines).

Hazardous decomposition products: Hydrocarbons, carbondioxide and -monoxid. No hazardous decomposition products if used and stored according to specifications.

Additional information: Emergency procedures will vary depending on conditions. The customer should have an emergency response plane in place.

Disposal considerations

· Recommendation: After diluting with a suitable desentisation agent to 10 %, the solution must be supplied to a special treatment (e. g. thermal utilization) under observance of all official regulations. Must not be disposed together with household garbage. Do not allow product to reach sewage system.

· Waste disposal key: Please contact your hazardous waste disposers to assign the right EWC-(European waste catalog)-number.

· Uncleaned packaging: Recommendation: This material and its container must be disposed of as hazardous waste.