Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-05-17 to 2016-05-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
2012
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Version / remarks:
1996
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
Version / remarks:
1999
Qualifier:
according to guideline
Guideline:
other: CIPAC Guideline MT 22: Viscosity
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.99
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.76
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.18
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.92
Conclusions:
The dynamic viscosity of the test item was determined to be 0.99 mPa*s (20°C) and 0.76 mPa*s (40°C).
Executive summary:

The viscosity of the test item was determined according to GLP and OECD 114 Viscosity of liquids.

The viscosity was determined via capillary viscometer. Two test series of 2 measurements, respectively, at temperatures of 20°C and 40°C were performed.

The kinematic viscosity of the test item was determined to be 1.18 mmE2/s (20°C) and 0.92 mmE2/s (40°C).

The dynamic viscosity of the test item was determined to be 0.99 mPa*s (20°C) and 0.76 mPa*s (40°C).

Description of key information

The dynamic viscosity of the test item was determined to be 0.99 mPa*s (20°C) and 0.76 mPa*s (40°C).

Key value for chemical safety assessment

Viscosity:
0.99 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The viscosity of the test item was determined according to GLP and OECD 114 Viscosity of liquids.

The viscosity was determined via capillary viscometer. Two test series of 2 measurements, respectively, at temperatures of 20°C and 40°C were performed.

The kinematic viscosity of the test item was determined to be 1.18 mmE2/s (20°C) and 0.92 mmE2/s (40°C).