Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 April 2018 to 06 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Observed to ignite and burn at point of contact with the burner flame. The flame propagated along a 200 mm length of the train in a total of 10 mins and 34 sec. As this was longer than the limit of 4 minutes, no further testing was necessary.
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test was determined to be not highly flammable.
Executive summary:

The flammability of the test item was determined in an EU Method A.10 guideline study. The test item was observed to ignite and burn at point of contact with the burner flame. The flame propagated along a 200 mm length of the train in a total of 10 minutes and 34 seconds. As this was longer than the limit of 4 minutes, no further testing was necessary. The test item was determined to be not highly flammable.

The study is a GLP compliant, guideline experimental study and is fully acceptable for this endpoint.

Description of key information

The test item was found to be not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test item was investigated in an EC Method A.10 study (Dunning 2018). The test item was found to be not highly flammable in a preliminary test.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Justification for classification or non-classification

Based on the results of a GLP compliant study following a standard test guideline, the substance does not require classification as a flammable solid.