Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ISO) without GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
ISO 2592
Deviations:
no
GLP compliance:
no
Type of method:
open cup
Flash point:
295 °C
Atm. press.:
1 010 mBar

Triple determination

Temperature of first ignition trial: 280 / 280 / 280 °C

Ignitions/min: 5 -6 / 5 -7 / 5 -8

Ignition temperature: 292 / 296 / 296

Executive summary:

The flash point was measured with the open cup method to be 295 °C at atmospheric pressure.

Description of key information

295 °C at 1010 mbar

Key value for chemical safety assessment

Flash point at 101 325 Pa:
295 °C

Additional information