Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 Aug 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Commission Regulation (EC) No 440/2008 (as amended) of 30 May 2008, Part A: Methods for the determination of physico-chemical properties.
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH FLP Automatic Flash point tester
Remarks:
Continuously closed cup, electric arc method according to ASTM D 6450
Key result
Flash point:
166.2 °C
Atm. press.:
101.325 kPa
Interpretation of results:
other: Not Classified (EU Criteria)
Conclusions:
Under the conditions of the study, the Flash point of test item was determined to be 166.2°C.
Executive summary:

The flash point of the test substance was investigated in accordance with the standard ASTM D 6450. using a MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method

The flash point was measured in duplicate

Under the conditions of this study, the flash point was determined to be 166.2°C.

Description of key information

The flash point of the test substance Solvent Red 19T was determined to be 166.2°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
166.2 °C

Additional information

The flash point of the test substance was investigated in accordance with the standard ASTM D 6450. using a MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method

The flash point was measured in duplicate

Under the conditions of this study, the flash point was determined to be 166.2°C.