Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes
Type of method:
effusion method: Knudsen cell

Test material

1
Chemical structure
Reference substance name:
Reaction products of 2-Ethylaniline with heptyl naphthalen-2-ol
Cas Number:
1401000-07-4
Molecular formula:
Not applicable (UVCB Substance)
IUPAC Name:
Reaction products of 2-Ethylaniline with heptyl naphthalen-2-ol
Test material form:
solid
Specific details on test material used for the study:
Batch number: 80-47-16

Results and discussion

Vapour pressureopen allclose all
Test no.:
#1
Temp.:
27.4 °C
Vapour pressure:
0.078 Pa
Test no.:
#2
Temp.:
33.3 °C
Vapour pressure:
0.074 Pa
Test no.:
#3
Temp.:
39.4 °C
Vapour pressure:
0.119 Pa
Test no.:
#4
Temp.:
45.8 °C
Vapour pressure:
0.238 Pa
Test no.:
#5
Temp.:
52.8 °C
Vapour pressure:
0.486 Pa
Test no.:
#6
Temp.:
59.8 °C
Vapour pressure:
0.944 Pa
Test no.:
#6
Temp.:
67.2 °C
Vapour pressure:
1.17 Pa
Test no.:
#7
Temp.:
75 °C
Vapour pressure:
1.58 Pa
Test no.:
#8
Temp.:
82.2 °C
Vapour pressure:
2.14 Pa

Any other information on results incl. tables

Since the analysis was conducted under high vacuum conditions, the heat could be transferred only by radiation, this caused a consistent difference between the furnace temperature and the sample one and a considerable time for the system to reach equilibrium.

The temperatures reported (registered by the thermocouple under the Knudsen cell) are hence different from the one set and the mass loss has been measured only in 80 minutes time interval within each isotherm, after the system had reached equilibrium.

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test item is 0.0313 Pa at 20°C (extrapolated value).