Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-09-03 to 2019-09-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
N,N'-[(methylimino)dipropane-1,3-diyl]dioleamide
EC Number:
256-233-5
EC Name:
N,N'-[(methylimino)dipropane-1,3-diyl]dioleamide
Cas Number:
45320-65-8
Molecular formula:
C43H83N3O2
IUPAC Name:
(9Z)-N-{3-[methyl({3-[(9Z)-octadec-9-enamido]propyl})amino]propyl}octadec-9-enamide

Test animals / tissue source

Details on test animals or tissues and environmental conditions:
- Justification of the test method and considerations regarding applicability
The EpiOcular™ Eye Irritation Test (EIT) predicts the acute eye hazard potential of chemicals by measurement of its tissue damage caused by cytotoxic effects in the reconstructed human cornea-like tissue model.
Within a tired testing strategy, the EpiOcular™ EIT is used as areplacement of the in vivo Draize Eye Irritation Test.
It is utilized for the classification and labelling of ehernieals concerning their eye hazard potential.
The EpiOcular™ EIT can be used to identify ehernieals that do not require classification for eye irritation or serious eye damage according to the UN GHS classification system.
A limitation of this guideline is that it neither allows discrimination between eye irritation/reversible effects on the eye (Category 2) and serious eye damage/irreversible effects on the eye (Category 1), nor between eye irritants (optional Category 2A) and mild eye irritants (optional Category 2B). For these purposes, further testing with other suitable test methods is required.

- Description of the cell system used, incl. certificate of authenticity and the mycoplasma status of the cell live
The EpiOcular™ tissue consists of normal, human-derived keratinocytes which have been cultured to form a stratified squamous epithelium similar to that found in the human cornea.
It consists of highly organized basal cells. These cells are not transformed or transfected with genes to induce an extended life span.
The EpiOcular™ tissues are cultured in specially prepared cell culture inserts with a porous membrane through which nutrients can pass to the cells.
Certificate of analysis is available for tissues, confirming cell source, absence of biological contaminants and analysis of quality and functionality.

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
Test substance:
50 mg
Positive and negative control: 50 µl for each
Duration of treatment / exposure:
6 hours
Duration of post- treatment incubation (in vitro):
18 hours
Number of animals or in vitro replicates:
duplicate
Details on study design:
Details of the test procedure used

- RhCE tissue construct used, including batch number
EplOcular™Tissue, MatTek Lot: 27029

- Doses of test chemical and control substances used : 50 mg of test substance, each 50µL of negative and positive control

- Duration and temperature of exposure, post-exposure immersion and post-exposure incubation periods (where applicable)
After dosing the last tissue, all plates were transferred into the incubator for 6 hours at 37 ± 1 °C, 5 ± 1 % CO2 and ~ 95 % relative humidity.
At the end of exposure time, the inserts were removed from the plates in one-minuteintervals using sterile forceps and rinsed immediately. The inserts were thoroughly rinsed with DPBS.
Then, the tissues were immediately transferred into 5 mL of assay medium in pre-Iabelled 12-well plate for 25 minutes post soak at room temperature.
For post-treatment incubation, the tissues were incubated for 18 hours at 37 ± 1 °C, 5 ± 1 % C02 and ~ 95 % relative humidity.

- Indication of controls used for direct MTT-reducers and/or colouring test chemicals (if applicable)
The test item was tested for the ability of direct MTT reduction.
The colour of the MTT turned blue/purple, therefore the test item is presumed to have reduced the MTT.

- Number of tissue replicates used per test chemical and controls (positive control, negative control, NSMTT, NSCliving and NSCkilled, if applicable)
duplicate tissues were used

- Wavelength and band pass (if applicable) used for quantifying MTT formazan, and linearity range of measuring device (e.g. spectrophotometer)
The wavelength used in the test is 570 nm.
Quarterly, a calibration of the microplate reader by using a calibration plate provided by the manufacturer is performed in order to ensure the linearity of photometric measurements.
The plate photometer has an indication range for optical density (OD) between 0.0 and 3.3 and a linear range of 0.1 - 2.5. Only measurements made within the linear range are used for the quantitative calculations.

- Description of the method used to quantify MTT formazan
Microtiter plate photometer, Anthos Reader 2010 Flexi, Anthos Microsysteme GmbH

- Reference to historical positive and negative control results demonstrating suitable run acceptance criteria
Values for negative control and for positive control were within the range of historical data of the test facility.
All validity criteria were met, therefore the experiment is considered valid.

- Demonstration of proficiency in performing the test method before routine use by testing of the proficiency chemicals
The validity of the EpiOcular™ test at test lab was demonstrated in a proficiency study.
For this purpose 15 proficiency ehernieals (indicated by the OECD 492 guideline) were tested. All of the 15 proficiency ehernieals were correctly categorized.

- Positive and negative control means and acceptance ranges based on historical data
% mean relative viability of positive control: < 50 % of negative control

- Acceptable variability between tissue replicates for positive and negative controls
< 20 % (test: 0.3% (negative control); 3.3% (positive control)

- Acceptable variability between tissue replicates for the test chemical
< 20 % (test: 1.1 % (test item)

Results and discussion

In vitro

Results
Irritation parameter:
other: % Tissue Viability Mean
Run / experiment:
Experiment 1
Value:
98.3
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
The test item did not show any colour development in isopropanol.
The result of this pre-test was that the colour of the MTT turned blue/purple, therefore the test item has shown its ability to reduce MTT.
Therefore, it was necessary to perform an additional test with freeze killed tissues that possess no metabolic activity but absorb and bind the test item like viable tissues.
Results showed that the MTT reduction by the test item did not influence the result of the main test.

All validity criteria were met. The criterion for optical density of the negative control was fulfilled: The OD value was 2.0 (> 0.8 and < 2.5).
The positive control induced a decrease in tissue viability as compared to the negative control to 28.0%.
The variation within the replicates of the controls and the test item was acceptable (< 20%).
For these reasons, the result of the test is considered valid.

Any other information on results incl. tables

Absorbance Values Negative Control, Positive Control and Test Item (OD at 570 nm)

 

 

Measurement

Negative Control

Positive Control

Test substance

Tissue 1

1

1.989

0.545

2.005

 

2

2.044

0.572

1.935

 

Tissue 2

1

2.025

0.623

1.987

 

2

1.997

0.624

1.998

 

 

Absorbance Values of Negative Control and Test Item with Freeze-killed Tissues (OD at 570 nm)

 

 

Measurement

Negative Control

Test substance

Tissue 1

1

0.078

0.066

2

0.076

0.063

Tissue 2

1

-

0.073

2

-

0.073

 

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Under the conditions of the test, N,N'-[(methylimino)bis(trimethylene)]bis(oleamide) is considered non-eye irritant in the EpiOcular™ Eye Irritation Test.
Executive summary:

An in-vitro eye irritation study was conducted using the EpiOcular™ Reconstructed human Cornea-like Epithelium (RhCE) test method according to OECD guideline 492 with the test substance N,N'-[(methylimino)bis(trimethylene)]bis(oleamide).

 

Since in the pre-test, potential MTT reduction by the test item was observed, an additional test was performed to correct photometrical measurement values due to direct MTT reduction by the test item. The results of the additional test showed that the MTT reduction by the test item did not influence the result of the main test.

 

The test item N,N'-[(methylimino)bis(trimethylene)]bis(oleamide) was applied to a three dimensional human cornea tissue model in duplicate for an exposure time of 6 hours.

After treatment, the test item was rinsed off the tissue; then, cell viability of the tissues was evaluated by addition of MTT, which can be reduced to formazan. The formazan production was evaluated by measuring the optical density (OD) of the resulting solution.

 

Demineralised water was used as negative control and methyl acetate was used as positive control.

After treatment with the negative control, the absorbance values were within the required acceptability criterion of mean OD > 0.8 and <2.5, the OD was 2.0.

The positive control showed clear eye irritating effects, the mean value of the relative tissue viability was 28.0% (< 50%).

The variation within tissue replicates of the controls and the test item was acceptable(< 20%).

 

After treatment with the test item, the mean value of relative tissue viability was 98.3%. This value is well above the threshold for eye irritation potential (≤ 60%).

Test items that induce values above the threshold are considered non-eye irritant.

Under the conditions of the test, N,N'[(methylimino)bis(trimethylene)]bis(oleamide) is considered non-eye irritant in the EpiOcular™ Eye Irritation Test.