Administrative data

Endpoint:
oxidising liquids
Type of information:
other: Statement
Adequacy of study:
key study
Study period:
4 March - 18 April 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Based on the molecular structure, a statement rather than a full study was considered sufficient to cover this endpoint.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
3-(C6-16, (even numbered) and C16 unsaturated alkyl)-4-(C7-17 (odd numbered) and C17 unsaturated alkylidene)-oxetan-2-one
EC Number:
700-132-5
Cas Number:
863782-35-8
Molecular formula:
See remarks.
IUPAC Name:
3-(C6-16, (even numbered) and C16 unsaturated alkyl)-4-(C7-17 (odd numbered) and C17 unsaturated alkylidene)-oxetan-2-one
Details on test material:
- Name of test material (as cited in study report): Aquapel® 203
- Substance type: yellow fatty liquid
- Physical state: liquid
- Analytical purity: 89.9%
- Lot/batch No.: G12FY067
- Expiration date of the lot/batch: 12 June 2008
- Stability under storage conditions: stable
- Storage condition of test material: at room temperature in the dark

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information)
Parameter:
other: not specified (migrated information)
Remarks on result:
other: result not specified (migrated information)
Remarks:
Please see the statement below.
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information)
Parameter:
other: not specified (migrated information)
Remarks on result:
other: result not specified (migrated information)
Remarks:
Please see the statement below.

Any other information on results incl. tables

Examination of the molecular structure of the intended product, present for 89.9% inthe test substance, establishes beyond reasonable doubt that the substance is incapable of showing a positive result in the test described in the EC A.21 guideline. The substance does not contain any group that might act as an oxidizing agent. The oxygen atoms that are present in the substance are bonded to carbon, which indicates that the molecule is oxygen-deficient. This is also the case for the test substance related components present for±10% of the test substance. The components present for < 1% were not taken into account but it is not to be expected that these have any influence. It is not to be expected that an interaction between the different components occur resulting in an oxidizing chemical.

In conclusion, Aquapel®203 has no oxidizing properties.

 

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
Aquapel®203 has no oxidizing properties.