Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
other: data from study report
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: data from GLP study report
Qualifier:
no guideline followed
Principles of method if other than guideline:
The appearance was mentioned in the test material section of the study report. The characterization of the test item was conducted under a sponsor or sponsor subcontractor quality system.
GLP compliance:
no
Physical state at 20°C and 1013 hPa:
solid
Key result
Form:
solid: particulate/powder
Colour:
White
Odour:
other: Not determined
Substance type:
organic

Decsription in study report: white crystal powder

Conclusions:
The substance is a white crystal powder at room temperature.
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 November 2017 - 11 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Version / remarks:
1998
Deviations:
no
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
231 °C
Decomposition:
yes
Remarks on result:
other: Decomposition started during melting.

TGA EXPERIMENT (PRELIMINARY TEST)

Significant decrease of weight from 275°C. 25% weight loss at 362°C and 51% weight loss at 549°C.

After the experiment, a black charred expended residue remained in the sample container (original colour: white) and a black residue was observed on the lid of the sample container. The change of the colour indicated reaction and/or decomposition of the test item.

DSC EXPERIMENT 1

 An endothermic peak was observed between 200°C and 250°C directly followed by an exothermic effect starting at 275°C. The extrapolated onset temperature of the first peak was 230.980°C. The endothermic effect was most likely obtained due to melting of the test item. The exothermic effect was probably obtained due to reaction and/or decomposition of the test item. After the experiment, a yellow expended residue remained in the sample container (original colour: white) and a yellow residue was observed on the lid of the sample container. Based on this visual observation, it was found that the test item had molten and the change of the colour demonstrated reaction and/or decomposition of the test item.

DSC EXPERIMENT 2

In order to investigate the melting peak, Experiment 2 was stopped directly after the melting peak. The extrapolated onset temperature was 230.974°C. After the experiment, a yellow white molten residue remained in the sample container. The change of the colour indicated reaction and/or decomposition of the test item. It demonstrated that melting was the reason for the endothermic effect.

DATA HANDLING

The melting temperature was determined as the mean of the extrapolated onset temperature of Experiment 1 and Experiment 2.

Conclusions:
The melting temperature of the substance was determined to be 231°C.

Executive summary:

Differential Scanning Calorimetry (DSC) experiments were performed in a GLP study according to EC A.1, OECD 102 and OPPTS 830.7200.

The melting temperature of the substance was determined in duplicate obtaining a mean value of 231°C.

Reaction and/or decomposition of the substance started during melting.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion