Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
adopted 13. April 2004;
resp. EU A.8
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Bruggolen® H3301
Batch no. 16101213
Production date 12. Oct. 2016
Expiry date 12. Oct. 2026
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
ca. 5.5
Temp.:
25 °C
pH:
ca. 6

Measurement Data

The retention times (RT) of the test item are presented in the following table:

 Measurement RT (min) 
  Measurement 1 19.074 
  Measurement 2  19.100
  Measurement 3

 19.134

 Mean 19.102 
 Standard deviation 0.030 

Calculated values

The calculated values are presented in the following table:

 Measurement  Capacity Factor k  log Capacity Factor log k  log POW
  Measurement 1  12.6448 1.1019  5.493 
  Measurement 2  12.6637 1.1026  5.495 
  Measurement 3  12.6877 1.1034  5.497 
 Mean     5.495 
 Relative Standard deviation      0.002

log POWwas calculated from the capacity factor as follows:

 log POW= (log k + 0.7919) / 0.3448

Using the correlation log k / log POW, the log POWof test itemIodobis(triphenylphospino)copperwas calculated as 5.50 ± 0.00 (mean ± standard deviation).

Conclusions:
Variations in the retention times of reference items and test item are very small. Therefore a stable configuration of the HPLC-column can be assumed.
The correlation log k/log POW is good: the coefficient of determination r2 was calculated with 0.9934. This value was considered as sufficiently high to use the calibration function for the determination of the log POW of the test item Iodobis(triphenylphospino)copper.
Using the correlation log k / log POW, the log POW of test item Iodobis(triphenylphospino)copper was calculated as 5.50 ± 0.00 (mean ± standard devia-tion).
No observations were made which might cause doubts concerning the validity of the study outcome.
Executive summary:

The study was performed using a HPLC with a C18 column.Eightreference items with different retention times and thiourea for the determination of the dead time were used to produce a calibration curve, since retention time on hydrophobic columns and POWare correlated. The reference items were chosen based on the results of the pre-test.


One vial was filled with the reference item mix and one vial with the test item solution. The vials were analysed using the HPLC with the program described below. First one injection from the solvent blank methanol/water 75/25 % (v/v) was made. Then three injections were measured from the reference item mix, three injections from the test item and again three injections from the reference item mix.


For each reference item, the capacity factor k was calculated from the retention time of thiourea and the retention time of the respective reference item.

A calibration function (log k versus log POW, linear fit) was determined using the literature values for POWof the reference items and the retention times in the six determinations.

With the calibration function log k versus log POW, the corresponding log POWvalues of the peak was determined:

Using the correlation log k / log POW, the log POWof test itemIodobis(triphenylphospino)copperwas calculated as

5.50 ± 0.00

(mean ± standard deviation of three independent determinations).

Description of key information

The log POW of test item Iodobis(triphenylphospino)copper was calculated as 5.50 ± 0.00.

Key value for chemical safety assessment

Log Kow (Log Pow):
5.5
at the temperature of:
25 °C

Additional information