Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
before 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: DIN 51758
Version / remarks:
DIN 51758
Deviations:
not specified
Remarks:
estimation method applied
Principles of method if other than guideline:
no decision possible on the available data
GLP compliance:
not specified
Remarks:
DIN 51758
Type of method:
other: determination of flash point by Pensky-Martens closed tester
Remarks:
determination of flash point by Pensky-Martens closed tester
Flash point apparatus:
Abel-Pensky apparatus

Test material

Constituent 1
additive 1
Test material form:
liquid
Details on test material:
- State of aggregation: not applicable
- Activation: not required
water as a additive
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: The test material is representative of the registered substance
- Expiration date of the lot/batch: not relevant
- Purity test date: not relevant

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature in the dark
- Stability under test conditions: stable
- Solubility and stability of the test substance in the solvent/vehicle: soluble

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: none
- Preliminary purification step (if any): none

Results and discussion

Flash point
Key result
Remarks on result:
not determinable, other reason:
Remarks:
no decision possible on the available data

Applicant's summary and conclusion

Interpretation of results:
other: no decision possible on the available data
Conclusions:
experimental flash point study ordered
Executive summary:

Using an estimation according to DIN 51758, no flash point was derived, and an experimental flash point study was ordered