Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Industrial batch 2013120001 (Lab. ID: LP-002861 S01)
Key result
Flash point:
167 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item is 167°C.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
167 °C

Additional information