Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 Dec 2018 to 25 Jan 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
March 04, 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Version / remarks:
July 27, 1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Version / remarks:
August 1996
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
Physical Description: White powder
Purity/Composition: 99.2%, assumed 100% for testing
Storage Conditions: At room temperature protected from light desiccated
Key result
Decomposition:
yes
Decomp. temp.:
300 °C
Conclusions:
The boiling temperature of Esacure A 198 were determined by DSC.

Reaction and/or decomposition of the test item was observed during DSC experiment starting at 300°C (573K). Boiling of the test item was not observed below the temperature at which reaction and/or decomposition started. Based on this, the test item has no boiling temperature.
Executive summary:

In this guideline (OECD 103) study, conducted with GLP certification, the test item EC 466-080-8 was shown to decompose at 300 °C.

Description of key information

Study conducted to recognised testing guidelines with GLP certification.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
300 °C

Additional information

Test item decomposes at 300 °C