Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
According to Directive 92/69/EEC and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
Directive 92/69/EEC, Annex V, A.10
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks:
t
Burning time:
> 2 min
Remarks on result:
other: short ignition without inflammation with spreading within 2 minutes

Any other information on results incl. tables

the test substance showed a short ignition but there was no inflammation with spreading observed within 2 minutes.

Therefore, the main test had not to be conducted.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance has not to be classified as flammable solid according to Regulation (EC) No 1272/2008.