Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 May 2019
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D92
GLP compliance:
no
Type of method:
open cup

Test material

Constituent 1
Reference substance name:
Heavy wax residue fraction, waste plastic derived, hydrothermal conversion
Molecular formula:
Not applicable - UVCB
IUPAC Name:
Heavy wax residue fraction, waste plastic derived, hydrothermal conversion
Test material form:
other: solid - lumps
Details on test material:
- Stability: stable under storage conditions
- Storage: room temperature (20 ± 5 °C)
- Appearance: large, brown, solid lumps
- Purity: not applicable, UVCB
- Homogeneity: homogeneous
- EC no.: 950-445-8

Results and discussion

Flash point
Key result
Flash point:
340 °C
Remarks on result:
other: Corrected flash point

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The corrected flash point was determined to be 340 °C