Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 9 november 2020 to 10 november 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
dynamic method
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
> 0.001 Pa
Conclusions:
The vapour pressure of the test item was considered to be largely lower than 10-3 Pa at 20 °C.
Executive summary:

VAPOUR PRESSURE
In compliance with Regulation (EC) No. 1907/2006, Council Regulation (EC) No. 761/2009
EC A.4. method (2009) and OECD Guideline No. 104 (2006)
The vapour pressure of the test item was considered to be largely lower than
10-3 Pa at 20 °C.

Description of key information

The vapour pressure of the test item was considered to be largely lower than 10-3 Pa at 20 °C.

Key value for chemical safety assessment

Vapour pressure:
0.001 Pa
at the temperature of:
20 °C

Additional information