Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 March 2013 to 21 August 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Key result
Temp.:
25 °C
Vapour pressure:
< 0.004 Pa
Remarks on result:
other: The test item did not change in appearance under the conditions used in the determination.
Conclusions:
The vapor pressure of the test material has been determined to be less than 4.2E-03 Pa at 25°C.
Executive summary:

In an OECD 104 study, conducted according to GLP, the vapour pressure of the test material is less than 0.0042 Pa at 25°C.

Description of key information

In an OECD 104 study, conducted according to GLP, the vapour pressure of the test material is less than 0.0042 Pa at 25°C.

Key value for chemical safety assessment

Vapour pressure:
0.004 Pa
at the temperature of:
25 °C

Additional information