Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: according to EC Directive 92/69/EEC and Regulation EC/440/2008 guideline methods under GLP conditions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes
Type of method:
HPLC estimation method

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
473-730-4
EC Name:
-
Cas Number:
928768-73-4
Molecular formula:
C13H28SO3
IUPAC Name:
1-Octanol reaction products with epichlorhydrin and 2-mercaptoethanol
Test material form:
liquid: viscous

Study design

HPLC method

Details on study design: HPLC method:
The sample, formamide and reference standard solutions were injected in duplicate using the following HPLC parameters:

HPLC System:
Agilent Technologies 1050, incorporating autosampler and workstation

Column:
Phenosphere Next CN 5µ (250 x 4.6 mm id)

Column temperature:
30°C

Mobile phase:
methanol:water (55:45 v/v)

pH of mobile phase:
6.9

Flow-rate:
1 ml/min

UV detector wavelength:
210 nm

Injection volume:
10 µl

Batch equilibrium or other method

Computational methods:
Using the Episuite software (Version 3.1 1 June 10th 2003, US EPA 2000) a result of log 10 Koc, 1.00 was obtained.

Results and discussion

Adsorption coefficient
Type:
log Koc
Value:
2.77
Temp.:
30 °C
Remarks on result:
other: none

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
Koc 593, log Koc 2.77, using the HPLC screening method, Method C19 of Commission Directive 2001/59/EC. However, due to the surfactant properties of the test material, a computer-based estimation of adsorption coefficient may be more reliable. Using the Episuite software (Version 3.1 1 June 10th 2003, US EPA 2000) a result of log 10 Koc, 1.00 was obtained.
Executive summary:

Koc 593, log Koc 2.77, using the HPLC screening method, Method C19 of Commission Directive 2001/59/EC. However, due to the surfactant properties of the test material, a computer-based estimation of adsorption coefficient may be more reliable. Using the Episuite software (Version 3.1 1 June 10th 2003, US EPA 2000) a result of log 10 Koc, 1.00 was obtained.