Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
(2S)-1,1-bis(4-fluorophenyl)propan-2-yl L-alaninate hydrochloride
Cas Number:
2171323-89-8
Molecular formula:
C18H20CIF2NO2
IUPAC Name:
(2S)-1,1-bis(4-fluorophenyl)propan-2-yl L-alaninate hydrochloride
Specific details on test material used for the study:
Substance name: BFPA HCl salt
Lot #: SS17000577 (TSN400390)
Purity: 100%

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test over 100 mm length
Remarks on result:
other: not ignite at all during the two minutes of application of the test flame

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Not a highly flammable solid
Executive summary:

The test is conducted according to EC Testing Method A.10 and OCSPP 830.6315 to determine the burning rate of any substance that can be ignited.


The test item was observed to melt at point of contact with the test flame. The material did not ignite at all during the two minutes of application of the test flame.


The test substance was not highly flammable.