Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Type of method:
static method

Test material

Results and discussion

Vapour pressureopen allclose all
Temp.:
36.58 °C
Vapour pressure:
0.72 Pa
Remarks on result:
other:
Temp.:
31.33 °C
Vapour pressure:
0.56 Pa
Remarks on result:
other:
Temp.:
24.16 °C
Vapour pressure:
0.38 Pa
Remarks on result:
other:
Temp.:
20 °C
Vapour pressure:
0.31 Pa
Remarks on result:
other:

Applicant's summary and conclusion