Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
10 Oct 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
Certificate of Analysis
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
GLP compliance:
no
Type of method:
capillary viscometer (static)
Temp.:
other: 25.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
33
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Remarks:
Certificate of Analysis
Principles of method if other than guideline:
Internal method ER020120
GLP compliance:
no
Standard covering the apparatus used:
No detailed information about the method is given.
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
16.5
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.25

Description of key information

33 mm²/s at 25 °C
16.5 mm²/s at 40 °C
3.25 mm²/s at 100 °C

Key value for chemical safety assessment

Additional information

The kinematic viscosity of the substance was determined by capillary method ASTM D445 at 25 °C and with an internal method (ER020120) at 40 °C and 100 °C.

.