Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.
Qualifier:
according to guideline
Guideline:
other: EN ISO 3838
Deviations:
no
GLP compliance:
no
Type of method:
pycnometer method
Key result
Type:
density
Density:
0.907 g/cm³
Temp.:
20 °C

Measurement

date of measurement: 20.06.2012

pycnometer volume (theory):49.997 ml

(bath) temperature: 20 °C

weight of empty pycnometer: 30.0539 g

weight of pycnometer with sample: 75.4105 g

weight of sample: 45.3566 g

density at given temperature: 0.907 g/cm³

Conclusions:
Average densitiy of date of Cyclohexanol, 4-C11-12-alkyl, branched: 0.907 mg/cm³ at 20 °C.
Executive summary:

The density of Cyclohexanol, 4-C11-12-alkyl, branched was determined to be 0.90.7 mg/cm³ at 20 °C according to EN ISO 3838.

Description of key information

The density of Cyclohexanol, 4-C11-12-alkyl, branched is 0.907 g/cm³ at 20 °C.

Key value for chemical safety assessment

Additional information