Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Justification for type of information:
QSAR prediction: migrated from IUCLID 5.6

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
no guideline available
Principles of method if other than guideline:
QSAR approach: Different tools were used, when possible, in order to apply a consensus approach and thus enhance the reliability of the predictions. In fact, a single in silico prediction model may provide acceptable results. However, by definition all models are simulation of reality, and therefore they will never be completely accurate; sometimes a single model will not work. When multiple models and multiple approaches are combined in a single consensus score, more accurate predictions can be achieved.
If two prediction methods that use data and different approaches are consistent, the reliability of prediction is better. The errors of a model/approach should be different from another, and therefore compensate.

Several computational tools are nowadays available for applying in silico approaches. Among them, for QSAR predictions the following was selected and used for the endpoint:
ACD/PhysChem Suite (Advanced Chemistry Development, Inc., Pharma Algorithms, Inc.) (release 2012) is a suite of comprehensive tools for the prediction of basic physicochemical properties. Predict logP, logD, aqueous solubility, pKa and an array of molecular properties in seconds, within one interface, and simply from chemical structure. The fragment-based models offer unsurpassed accuracy and cover a good breadth of chemical space, giving an instant insight into the properties and behaviour of the compounds of interest.
Estimation Program Interface (EPI) Suite (US Environmental Protection Agency’s Office of Pollution Prevention and Toxics and Syracuse Research Corporation (SRC), version 4.10) is a collection of several modules for the prediction of physicochemical and environmental fate endpoints developed by the Environmental Protection Agency (EPA) and by the Syracuse Research Corporation (SRC). It allows to transfer a single SMILES notation to thirteen separate structure estimation programs that calculate several properties such as octanol-water partition coefficient, water solubility, bioconcentration factor, vapour pressure
GLP compliance:
no
Type of method:
other: in silico prediction

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl 3-α,7-α-diacetoxy-12-α-hydroxy-5-β-cholan-24-oate
EC Number:
223-151-6
EC Name:
Methyl 3-α,7-α-diacetoxy-12-α-hydroxy-5-β-cholan-24-oate
Cas Number:
3749-87-9
Molecular formula:
C29H46O7
IUPAC Name:
methyl 3-α,7-α-diacetoxy-12-α-hydroxy-5-β-cholan-24-oate

Results and discussion

Water solubility
Water solubility:
-6 other: mol/L
Remarks on result:
other: Temperature and pH not available

Any other information on results incl. tables

Name

ACD/Labs LogS0 GALAS LogSw

(mol/l) (RI)

ACD/Labs

LogSw (mol/l)

EPI WSKowWIN LogSw (mol/l)

EPI

WATERNT

LogSw (mol/l)

CONSENSUS

quantitative

LogSw (mol/l)

CONSENSUS

Solubility

Qualitative

methyl 3-α,7-α-diacetoxy-12-α-hydroxy-5-β-cholan-24-oate

-5.59 (0.48)

-6.01

-7.00

-6.08

-6.00

Insoluble

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): slightly soluble (0.1-100 mg/L)
The Log Sw of the test item is -6.00 mol/L