Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 22 - November 25, 1996
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study has been performed according to EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report date:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: Directive 92/69/EEC, A.9 "closed cup"
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): Nikkol VC-IP
- Substance type: Colourless to light yellow transparent liquid
- Physical state: Liquid
- Stability under test conditions: stable
- Storage condition of test material: In refrigerator in the dark

Results and discussion

Flash point
Flash point:
226.5 °C
Atm. press.:
99.7 - < 101.1 kPa

Applicant's summary and conclusion

Conclusions:
In conclusion, the flash-point of NIKKOL VC-IP is 226.5°C under the conditions of the test.