Administrative data

First-aid measures

Inhalation: After inhalation move to fresh air. If shortness of breath occurs, support respiration and consult a physician.

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

Consult a physician if irritating symptoms develop and persist.

Skin Contact: Remove contaminated clothing. Rinse contaminated skin immediately with plenty of water and seek medical advice.

Eye Contact: Immediately rinse eyes thoroughly with running water as long as possible (approx. 15 min). Take injured quickly to factory medical center or call an ambulance (code word: eye accident).

Ingestion: If swallowed, seek medical advice immediately and show this container or label. Do not induce vomiting. In case of consciousness wash mouth with water and let drink some of water. Seek medical advice. Keep patient at rest.

Fire-fighting measures

Fire-fighting measures: Wear self-contained breathing apparatus and fire protective suite.

Accidental release measures

Accident release measures: All equipment and protective garments must be either decontaminated or properly contained for disposal before leaving the area.

Handling and storage

Handling storage: Provide appropriate exhaust ventilation at machinery and at places where dust can be generated. Keep container tightly closed in a dry, cool and well-ventilated place. Avoid formation of dust.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
No dangerous good
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
No dangerous good
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
No dangerous good
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
No dangerous good
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Industrial Hygiene The personal protective measure may be adapted appropriately when working in closed systems or under laboratory conditions.

Regular cleaning of equipment, work area and clothing.

No open handling without using reliable equipment. One technical barrier between substance

and employee resp. environment.

Restricted and controlled access for trained personnel only.

Designated washing, changing and shower facilities must be available.

Internal working procedures available to personnel covering personal hygiene,

decontamination /cleaning, consideration of worst case incidents, spills, emergency, alarms,

waste disposal and maintenance.

Personnel comprehensively instructed, highly trained and experienced. Regular refresher

training established including appropriate record keeping.

Equipment and protective garments must either be decontaminated or properly contained for

disposal before leaving the area.

Disposable protective equipment is to be decontaminated before removal (decontamination

shower).

Open Handling Respiration : Full face mask (EN136)

Filter : P3 (EN143)

Eye : Yes, by face mask

Hand : Normal length chemical-mechanical-resistant gloves (EN374/EN388)

worn over disposable gloves

Glove Material : Nitrile

Breakthrough time: 240 min

Thickness: 0.4 mm

Additional protection : Disposable dust-proof suit (EN465, type 4) worn over long underwear

Disposable boot covers, conductive

Stability and reactivity

Stable at normal conditions

Preventive Precautions (fire/explosion)

Take precautionary measures against static discharges. Keep away from sources of ignition.

Hazardous decomposition products: carbon oxides, nitrogen oxides

Disposal considerations

Fill into suitable waste receptacles, seal and label them properly. Incineration in an approved, controlled furnace with combustion gas scrubbing and emission gas control

Container Disposal For disposal local regulation is binding.