Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-02-01 to 2018-03-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
October 2, 2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
March 04, 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Version / remarks:
June 2002
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
air comparison pycnometer (for solids)
Dynamic viscosity of test material:
The test material is a solid
Key result
Type:
relative density
Density:
0.981 g/cm³
Temp.:
20 °C

 Results

The results of the tests on the determination of the density of the test item are given in Table 2 below.

The individual measurements were obtained with an accuracy of < 0.02 g/cm3. According to the guideline, the density of the test item is given as the mean value.

Table 2: Density of the Test Item

 

Test 1

Test 2

Mean

Density [g/cm3]

0.9780

0.9845

0.981

Conclusions:
Relative density (OECD 109; GLP): 0.981
Executive summary:

The relative density was determined for the test item Bis(hexamethylene)triamine according to OECD 109 and EU method A.3 compliant with GLP.

A gas comparison stereopycnometer was used for the determination of the density and relative density of the test item.

The density of the test item at 20ºC was 0.981 g/cm3 (arithemtic mean value, n= 2).

The relative density was 0.981.

Results of the single measurements were 0.9780 and 0.9845.

Description of key information

Relative density (OECD 109; GLP): 0.981

Key value for chemical safety assessment

Relative density at 20C:
0.981

Additional information

The relative density was determined for the test itemBis(hexamethylene)triamine according to OECD 109 and EU method A.3 compliant with GLP.

A gas comparison stereopycnometer was used for the determination of the density and relative density of the test item.

The density of the test item at 20ºC was 0.981 g/cm3(arithemtic mean value, n= 2).

The relative density was 0.981.

Results of the single measurements were 0.9780 and 0.9845.