Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Inhalation:


- If breathed in, move person into fresh air.


- Victim to lie down in the recovery position, cover and keep him warm.


- Oxygen or artificial respiration if needed.


- Immediate medical attention is required.


Eye contact:


- Keep eyelids open to allow evaporation of product.


- Flush eyes with running water for several minutes, while keeping the eyelids wide open.


- Immediate medical attention is required.


Skin contact:


- Allow to evaporate.


- Rinse with lukewarm running water.


- Call a physician immediately.


Ingestion:


- not applicable

Fire-fighting measures

Suitable extinguishing media:


- water


- powder


- Foam


- Dry chemical


- Carbon dioxide (CO2)


Unsuitable extinguishing media:


- None


Special hazards arising from the substance or mixture:
- Extremely flammable
- Flash back possible over considerable distance.


- Thermal decomposition can lead to release of toxic and corrosive gases.
- Explosion risk in case of fire.
- Vapours are heavier than air and may spread along floors.
- Risk of ignition.


Special protective equipment for fire-fighters:


- Wear self-contained breathing apparatus and protective suit.


- When intervention in close proximity wear acid resistant over suit.


Other information:


- Leaking gas fire: Do not extinguish, unless leak can be stopped safely.


- Evacuate personnel to safe areas.


- Approach from upwind.


- Protect intervention team with a water spray as they approach the fire.


- Keep containers and surroundings cool with water spray.


- Keep product and empty container away from heat and sources of ignition.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Advice for non-emergency personnel:
- Prevent further leakage or spillage if safe to do so.



Advice for emergency responders:
- The product evaporates readily.
- Ventilate the area.
- Suppress (knock down) gases/vapours/mists with a water spray jet.
- Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing.
- Cover the spreading liquid with foam in order to slow down the evaporation.
- Keep away from open flames, hot surfaces and sources of ignition.
- Refer to protective measures for Handling and storage and for Exposure controls/personal protection


Environmental precautions
- Should not be released into the environment.
- Do not flush into surface water or sanitary sewer system.



Methods and materials for containment and cleaning up
- Suppress (knock down) gases/vapours/mists with a water spray jet.
- Soak up with inert absorbent material.
- Suitable material for picking up.
- Earth
- Dry sand
- Shovel into suitable container for disposal.

Handling and storage

Precautions for safe handling
- Use only in well-ventilated areas.
- Keep away from heat and sources of ignition.


- Purge piping circuits and equipment with nitrogen.
- No sparking tools should be used.
- To avoid thermal decomposition, do not overheat.
- Use only explosion-proof equipment.
- Avoid skin contact with leaking liquid (danger of frostbite).
- Take measures to prevent the build up of electrostatic charge.



Hygiene measures:
- Ensure that eyewash stations and safety showers are close to the workstation location.
- Gloves, overalls and boots have to be double layered (protection against cold temperature).
- Take off contaminated clothing and shoes immediately.
- Wash contaminated clothing before re-use.
- When using do not eat, drink or smoke.
- Wash hands before breaks and at the end of workday.
- Handle in accordance with good industrial hygiene and safety practice.


 


Conditions for safe storage, including any incompatibilities


Technical measures/Storage conditions:
- Keep away from heat and sources of ignition.
- Keep in a cool, well-ventilated place.
- Vapours are heavier than air and may spread along floors.
- Keep away from direct sunlight.
- Keep in container fitted with safety valve or vent.
- Keep away from combustible material.
- Keep away from incompatible products
- Provide electrical equipment safe for hazardous locations.
- Ensure all equipment is electrically grounded before beginning transfer operations.
- Do not confine the product in a circuit, between closed valves, or in a container without a vent.
- Refer to protective measures for Handling and storage and for Exposure controls/personal protection.


 


Packaging material
Suitable material:
- Stainless steel
- Carbon steel
- Warning! Container under pressure.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3153
Shipping information
Proper shipping name and description:
PERFLUORO (METHYL VINYL ETHER)
Language:
English
Class or division:
Class 2: Gases; Division 2.1
Labels:
2.1
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3153
Shipping information
Proper shipping name and description:
PERFLUORO (METHYL VINYL ETHER)
Language:
English
Class or division:
Class 2: Gases; Division 2.1
Labels:
2.1
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 3153
Shipping information
Proper shipping name and description:
PERFLUORO (METHYL VINYL ETHER)
Language:
English
Class or division:
Class 2: Gases; Division 2.1
EmS code:
F-D
S-U
Labels:
2.1
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 3153
Shipping information
Proper shipping name and description:
PERFLUORO (METHYL VINYL ETHER)
Language:
English
Class or division:
Class 2: Gases; Division 2.1
Labels:
2.1
Special provisions / remarks
Special provisions:
Special precaution for user:

Packing instruction (cargo aircraft) : 200
Maz net qty/pkg: 150,00 kg
Packing instruction (passenger aircraft): not permitted for transport
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure Limit Values:


Trifluoro(trifluoromethoxy)ethylene


- SAEL (Solvay Acceptable Exposure Limit)


    TWA = 10 ppm


Control measures



Engineering measures
- Ensure adequate ventilation.
- Refer to protective measures for Handling and storage and for Exposure controls/personal protection.
- Apply technical measures to comply with the occupational exposure limits.



Individual protection measures



Respiratory protection
- Apply technical measures to comply with the occupational exposure limits.
- When workers are facing concentrations above the exposure limit they must use appropriate certified respirators: self-contained breathing apparatus.



Hand protection
- Wear protective gloves.
Suitable material:
- Neoprene gloves
- Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).



Eye protection


- Tightly fitting safety goggles



Skin and body protection
- Wear work overall and safety shoes.



Hygiene measures
- Ensure that eyewash stations and safety showers are close to the workstation location.
- Gloves, overalls and boots have to be double layered (protection against cold temperature).
- Take off contaminated clothing and shoes immediately.
- Wash contaminated clothing before re-use.
- When using do not eat, drink or smoke.
- Wash hands before breaks and at the end of workday.
- Handle in accordance with good industrial hygiene and safety practice.



Environmental exposure controls
- Dispose of rinse water in accordance with local and national regulations.

Stability and reactivity

Reactivity
- No dangerous reaction known under conditions of normal use.


Chemical stability
- Stable under recommended storage conditions.


Possibility of hazardous reactions
- Do not mix with polymerisation initiators., Hazardous polymerisation may occur.


Conditions to avoid


- Heat, flames and sparks.
- To avoid thermal decomposition, do not overheat.


Incompatible materials
- Acids
- Oxidizing agents
- Alkalis


Hazardous decomposition products
- Gaseous hydrogen fluoride (HF).
- Fluorophosgene
- The release of other hazardous decomposition products is possible.

Disposal considerations

Waste treatment methods



Product Disposal
- Can be incinerated, when in compliance with local regulations.
- The incinerator must be equipped with a system for the neutralisation or recovery of HF.
- Dispose of in accordance with local regulations.


Advice on cleaning and disposal of packaging
- Purge the container with nitrogen and direct the gas to a treatment plant.
- Empty containers can be landfilled, when in accordance with the local regulations.