Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Feburary 28, 2018 - March 7, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
flask method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
N-methyldiallylamine
EC Number:
219-354-4
EC Name:
N-methyldiallylamine
Cas Number:
2424-01-3
Molecular formula:
C7H13N
IUPAC Name:
methylbis(prop-2-en-1-yl)amine
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Lot 20160912
- Purity: 99.2%
- Density: 0.789 g/mL
- Expiration date of the lot/batch: June, 2018

Study design

Analytical method:
high-performance liquid chromatography
mass spectrometry

Results and discussion

Partition coefficient
Key result
Type:
Pow
Partition coefficient:
1.28
Temp.:
23.6 °C
pH:
6
Remarks on result:
other:
Remarks:
RSD% = 16% (n =12)
Details on results:
MTDID 49220 has measured Kow range from 0.944 - 1.57 for octanol-water ratios of 1:1, 1:2 and 2:1 (v/v). The overall average Kow is 1.28 (RSD% = 16%, n=12), calculates to log Kow of 0.107.

The total measured MTDID 49220 in the water and n-octanol phases had recoveries in the range of 77.3% to 88.3% (data not shown) compared to the dosed MTDID 49220.

Any other information on results incl. tables

Table 1: Summary of n-Octanol/Water Partition Coefficient (Kow) for MTDID 49220

 

 

Ratio

(n-Octanol: Aqueous)

Sample

Replicate

Conc. (ng/mL) in water phase

 

Conc.(ng/mL) in octanol phase

Kow

Avg. Kow

1:1

1

1

1330

1940

1.46

 

1:1

1

2

1400

1940

1.39

1.42

1:1

2

1

1560

1940

1.24

 

1:1

2

2

1560

1860

1.19

1.22

1:2

1

1

1070

1010

0.944

 

1:2

1

2

1060

1020

0.962

0.953

1:2

2

1

936

1220

1.30

 

1:2

2

2

973

1200

1.23

1.27

2:1

1

1

1960

2380

1.21

 

2:1

1

2

1980

2540

1.28

1.25

2:1

2

1

1660

2600

1.57

 

2:1

2

2

1650

2590

1.57

1.57

Overall Average

 

 

 

 

1.28

 

Overall RSD%

 

 

 

 

16%

(n = 12)

 

 

Applicant's summary and conclusion

Conclusions:
The Kow of MTDID 49220 was determined to be 1.28 at ambient temperature (23.6 ± 0.3 °C).
Executive summary:

The n-Octanol/Water Partition Coefficient (Kow) of MTDID 49220 was determined according to U.S EPA guidance document OPPTS 830.7550 "Partition Coefficient (n-Octanol/Water), Shake Flask Method".

Duplicate samples of MTDID 49220 were prepared in each of the three octanol/water ratios (1:1, 1:2 and 2:1). The samples were rotated 180 ° about their transverse axis for more than 50 rotations over 5 minutes at 30 RPM to ensure proper mixing of the test system solvents. The samples were then centrifuged at 1500 RPM for 10 minutes to ensure a clear separation of the aqueous and organic phases. Analysis samples were then prepared by first removing duplicate aliquots from the octanol phase, followed by removing duplicate aliquots of the aqueous phase. The sample aliquots were then appropriately diluted and analyzed using LC/MS/MS.

The determined Kow values ranged from 0.944 to 1.57 for all three octanol/water ratios. The overall average Kow was 1.28 (overall RSD% = 16%), calculates to log Kow of 0.107.

This is a guideline study.  Although it was not conducted under GLP compliance, the study was well documented, and achieved good accuracy and precision. Therefore, it is considered reliable without restrictions.