Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-05-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
76.5 °C
Atm. press.:
1 013 hPa





















Weight / gFlash point / °CAtmospheric pressure / hPaFlash point / °C corrected
75.276.11007.676.235
74.077.21007.677.335

 


The final flash point rounded down to 0.5 °C is 76.5 °C. 

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The flash point of Acrolein cyanhydrin acetate is 76.5 °C under atmospheric conditions (1013 hPa).

Description of key information

76.5 °C at 1013 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
76.5 °C

Additional information

GLP study according to ISO 2719 and EU Method A.9 using the Pensky-Martens closed cup method.