Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 February 2010 to 08 April 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
No. 440/2008-EC A16 Method (2008)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Batch No. LCE10033
- Expiration date of the lot/batch: 02 September 2010
- Purity test date: 11 March 2009

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: The test item was stored in darkness at room temperature.
Key result
Relative self-ignition temperature:
>= 422 °C
Remarks on result:
no self ignition observed under the test conditions

Assay No.1 :


-Duration of the test : 800 min

-Rate : 0.50°C/min

-Observations: At the start of the test, the test item was white flakes. At the end of the test, the cube filled with the test item was empty.

No self ignition temperature of the test item was observed up to 422°C


Assay No.2 :

-Duration of the test : 798 min

Rate 0.50°C/min

Observations: At the start of the test, the test item was white flakes . At the end of the test, the cube filled the test item was empty.

No self ignition temperature of the test item was observed up to 422°C

Conclusions:
No self ignition temperature of the test item was observed up to 422 °C.
Executive summary:

The objective of the test is to provide preliminary information on the auto flammability of the solid test item at elevated temperatures.

In compliance with Commission Directive 92/69/EEC, Commission Regulation (EC) No. 440/2008

EC A16 method (2008): A self ignition temperature test was performed to assess the auto flammability of the test item.


No self ignition temperature of the test item was recorded up to 422°C

Description of key information

In compliance with Commission Directive 92/69/EEC, Commission Regulation (EC) No. 440/2008

EC A16 method (2008): A self ignition temperature test was performed to assess the auto flammability of the test item.

No self ignition temperature of the test item was recorded up to 422°C

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
422 °C

Additional information