Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 December 2007 to 18 January 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
92/69/EEC A10 method (1992)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Batch No. : LCE07101
- Expiration date of the lot/batch:

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: The test item was stored in darkness at room temperature
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 2 min
Moisture (wt %):
16
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Preliminary test:


Experimental conditions:

-Humidity : About 16%

-Room temperature : About 20°C

-Atmospheric pressure : 99.2 kPa


Assay No.1

The test item melted under the effect of the flame, to form a colourless limpid liquid which evaporated.Neither inflamation nor propagation was observed.


Assay No.2

The same observations as for the assay No.1 were recorded.


Main test:

Taking into account the results obtained during the preliminary test, no main test was performed.

Conclusions:
The test item was not considered as highly flammable under our experimental conditions.
Executive summary:

The objective of the test was to determine whether a test item ignites according to the Commission Directive 92/69/EEC A10 method (1992):Flammability of solids.

The test item was not considered as highly flammable under our experimental conditions.

Description of key information

The objective of the test was to determine whether the test item ignites according to the Commission Directive 92/69/EEC A10 method (1992):Flammability of solids.

The test item was not considered as highly flammable under the experimental conditions.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification