Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 November 2010 to 19 November 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
This study was conducted in accordance with international guidelines in a GLP facility.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
3-trifluoromethylaniline
IUPAC Name:
3-trifluoromethylaniline
Details on test material:
Identification: 3-trifluoromethylaniline
Description: Extremely pale yellow liquid
Purity: 99.66 %
Batch Number: 101009
Date Received: 25 October 2010
Storage Conditions: Room temperature in the dark

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
> 400 °C
Atm. press.:
0.967 - 1.01 Pa
Remarks on result:
other:

Applicant's summary and conclusion

Conclusions:
The test item was determined not to have an auto-ignition temperature below 400 degrees celsius.