Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-131-3 | CAS number: 7440-22-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Test procedure in accordance with national standards DIN 55992-1:2006 ("Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method"), modified Heubach method no data for: - Analytical purity - Purity test date - Expiration date of the batch
- Qualifier:
- according to guideline
- Guideline:
- DIN 55992-1 (Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method)
- Version / remarks:
- 2006
- Deviations:
- yes
- Remarks:
- Modified Heubach-Method, in which the generated dust is not collected as a “bulk mass sample", but instead collected in a 7-stage cascade impactor, which allows a discrimination of the generated dust particles according to their aerodynamic diameters
- Principles of method if other than guideline:
- The Heubach dust meter is modified in a way that a seven stage cascade impactor is connected to the system. This involves an additional air fed of 20 L/min via the coarse dust separator needed to supply the cascade impactor with 40 L/min air current as specified in the manufacturer’s specificcations.
The calculation report: EBRC (2010)
The Multiple-Path Particle Dosimetry Model (MPPD, v2.0; CIIT, 2006) was used to predict this fractional deposition behaviour for workers.
The model algorithms calculate the deposition (and clearance) of mono-disperse and polydisperse aerosols in the respiratory tract for particles ranging from ultra-fine (0.01 microns) to coarse (20 microns) sizes. Within each airway, deposition is calculated using theoretically derived efficiencies for deposition by diffusion, sedimentation and impaction within the airway or airway bifurcation. Filtration of aerosols by the head is determined using empirical efficiency functions. - GLP compliance:
- no
- Type of method:
- rotating drum method
- Type of distribution:
- volumetric distribution
- Mass median aerodynamic diameter:
- 25.4 µm
- Geometric standard deviation:
- 2.8
- Percentile:
- D50
- Remarks on result:
- other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
- Conclusions:
- Silver Powder - Batch PMC 2
Total Dustiness (airborne fraction): 90.77 mg/g (experimental results, DMT Report).
Mass median aerodynamic diamater of airborne fraction: MMAD = 25.4 µm (distribution fitted to cascade impactor data).
Geometric standard deviation of MMAD: GSD = 2.8
Fractional deposition in human respiratory tract (MPPD model, based on calculated MMAD):
Head (ET): 50.1 %
Tracheobronchial (TB): 0.4 %
Pulmonary (PU): 0.7 % - Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Test procedure in accordance with national standards DIN 55992-1:2006 ("Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method"), modified Heubach method. no data for: - Analytical purity - Purity test date - Expiration date of the batch
- Qualifier:
- according to guideline
- Guideline:
- DIN 55992-1 (Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method)
- Version / remarks:
- 2006
- Deviations:
- yes
- Remarks:
- Modified Heubach-Method, in which the generated dust is not collected as a “bulk mass sample", but instead collected in a 7-stage cascade impactor, which allows a discrimination of the generated dust particles according to their aerodynamic diameters
- Principles of method if other than guideline:
- The Heubach dust meter is modified in a way that a seven stage cascade impactor is connected to the system. This involves an additional air fed of 20 L/min via the coarse dust separator needed to supply the cascade impactor with 40 L/min air current as specified in the manufacturer’s specificcations.
The calculation report: EBRC (2010)
The Multiple-Path Particle Dosimetry Model (MPPD, v2.0; CIIT, 2006) was used to predict this fractional deposition behaviour for workers.
The model algorithms calculate the deposition (and clearance) of mono-disperse and polydisperse aerosols in the respiratory tract for particles ranging from ultra-fine (0.01 microns) to coarse (20 microns) sizes. Within each airway, deposition is calculated using theoretically derived efficiencies for deposition by diffusion, sedimentation and impaction within the airway or airway bifurcation. Filtration of aerosols by the head is determined using empirical efficiency functions. - GLP compliance:
- no
- Type of method:
- rotating drum method
- Type of distribution:
- volumetric distribution
- Mass median aerodynamic diameter:
- 30.1 µm
- Geometric standard deviation:
- 1.7
- Percentile:
- D50
- Remarks on result:
- other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
- Conclusions:
- Silver Powder - Batch PMC 1
Total Dustiness (airborne fraction): 155.45 mg/g (experimental results, DMT Report).
Mass median aerodynamic diamater of airborne fraction: MMAD = 30.1 µm (distribution fitted to cascade impactor data).
Geometric standard deviation of MMAD: GSD = 1.7
Fractional deposition in human respiratory tract (MPPD model, based on calculated MMAD):
Head (ET): 45.3 %
Tracheobronchial (TB): 0.1 %
Pulmonary (PU): 0.0% - Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Information provided by a producer of silver metal powder.
- Principles of method if other than guideline:
- Various established methods/equipment for particle size distribution measurements were used, e.g. a Mastersizer 2000 or CILAS 1180.
- GLP compliance:
- no
- Type of method:
- other: Various established methods/equipment for particle size distribution measurements were used, e.g. a Mastersizer 2000 or CILAS 1180.
- Type of distribution:
- volumetric distribution
- Percentile:
- D50
- Remarks on result:
- other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
- Percentile:
- D10
- Mean:
- ca. 12 µm
- St. dev.:
- 0
- Remarks on result:
- other: Representative sample Batch PMC1
- Percentile:
- D50
- Mean:
- ca. 30 µm
- St. dev.:
- 0
- Remarks on result:
- other: Representative sample Batch PMC1
- Percentile:
- D90
- Mean:
- ca. 50 µm
- St. dev.:
- 0
- Remarks on result:
- other: Representative sample Batch PMC1
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Information provided by a producer of silver metal powder.
- Principles of method if other than guideline:
- Various established methods/equipment for particle size distribution measurements were used, e.g. a Mastersizer 2000 or CILAS 1180.
- GLP compliance:
- no
- Type of method:
- other: Various established methods/equipment for particle size distribution measurements were used, e.g. a Mastersizer 2000 or CILAS 1180.
- Type of distribution:
- volumetric distribution
- Percentile:
- D50
- Remarks on result:
- other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
- Percentile:
- D10
- Mean:
- ca. 0.8 µm
- St. dev.:
- 0
- Remarks on result:
- other: Representative sample Batch PMC2
- Percentile:
- D50
- Mean:
- ca. 2 µm
- St. dev.:
- 0
- Remarks on result:
- other: Representative sample Batch PMC2
- Percentile:
- D90
- Mean:
- ca. 11 µm
- St. dev.:
- 0
- Remarks on result:
- other: Representative sample Batch PMC2
Referenceopen allclose all
Dustiness (airborne fraction): total: 90.77 mg/g.
In the original study report by DMT, a calculation of the mass median diameter was not conducted. Since the deposited fractions were provided for each of the cascade impactor stages, it was possible to fit a mono modal lognormal distribution to the data by standard non-linear regression procedure. As a result, the MMAD and GSD are calculable and reported (MMAD = 25.4 µm, GSD = 2.8). As the cascade impactor already takes aerodynamic characteristics of the particles into account, the reported mass median diameter can be interpreted as the mass medianaerodynamicdiameter.
This figure and the corresponding GSD were used as distribution parameters for the MPPD model enabling an estimation of deposited dust fractions in the human respiratory tract: These fractions were estimated as follows:
Head (ET): 50.1 %
Tracheobronchial (TB): 0.4 %
Pulmonary (PU): 0.7 %
Dustiness (airborne fraction): total: 155.45 mg/g.
In the original study report by DMT, a calculation of the mass median diameter was not conducted. Since the deposited fractions were provided for each of the cascade impactor stages, it was possible to fit a mono modal lognormal distribution to the data by standard non-linear regression procedure. As a result, the MMAD and GSD are calculable and reported (MMAD = 30.1 µm, GSD = 1.7). As the cascade impactor already takes aerodynamic characteristics of the particles into account, the reported mass median diameter can be interpreted as the mass median aerodynamic diameter.
This figure and the corresponding GSD were used as distribution parameters for the MPPD model enabling an estimation of deposited dust fractions in the human respiratory tract: These fractions were estimated as follows:
Head (ET): 45.3 %
Tracheobronchial (TB): 0.1 %
Pulmonary (PU): 0.0 %
Description of key information
Silver is produced in various forms: powders (non-nano and nano-size) and massives (ingots, wires...).
Powders are produced with variable specifications, including various particle size distributions. Member companies of the Precious Metals Consortium have provided two representative samples of commercial non-nano silver metal powders (Batches PMC 1 and PMC 2) and provided particle size data. In addition to these specifications provided by the producers, experimental investigations on the dustiness (rotating drum method) and on the particle size distribution of material that becomes airborne during such tests have been performed.
Further, particle size data have been generated for the nanosilver forms covered by the REACH registration dossier (Nano sample 1 and 2).
Additional information
The particle size parameters for the two representative samples of silver metal powders (non-nano PMC 1 +2) are presented in the following format:
Batch: D10, D50, D90; Mass Median Aerodynamic Diameter of airborne dust (geometric standard deviation):
Batch PMC 1: 12 µm, 30 µm, 50 µm; 30.1 µm (1.7)
Batch PMC 2: 0.8µm, 2 µm, 11 µm; 25.4µm (2.8)
Further, two members of the Precious Metals REACH Consortium registering nanosilver have provided nanosilver products for physico-chemical characterisation. Nanosilver is usually marketed in suspension/wet powder form. The table below gives an overview of registered nanosilver products. For confidentiality reasons, the information on coatings and solvents has been omitted from the summary table below. The morphology was determined by visual inspection of TEM images. Quantitative analysis was done by TEM combined with ParticleSizer software. The volume specific surface area was calculated from the particle size (mean diameter).
Code | Type | Size of primary particles by TEM (Min. Feret diameter) | Morphology | Volume Specific Surface Area |
1 |
suspension/wetted powder |
Min = 5 nm, D25 = 7 nm, D50 = 8 nm, D75 = 9 nm, Max = 61 nm |
spherical |
714 m2/cm3 |
2 |
suspension/wetted powder |
Min = 11 nm, D25 = 25 nm, D50 = 34 nm, D75 = 48 nm, Max = 161 nm |
spherical |
150 m2/cm3 |
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.