EC number: 201-346-7 | CAS number: 81-39-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied
- Endpoint:
- pyrophoric solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- Endpoint:
- self-heating substances / mixtures
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2015
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study with acceptable restrictions
- Qualifier:
- according to guideline
- Guideline:
- other: German standard method "VDI 2263, Sheet 1"
- Deviations:
- no
- GLP compliance:
- no
- Other quality assurance:
- ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
- Key result
- Test procedure:
- other: Warm storage behavior by means of a wire basket
- Max. temp. reached:
- 219
- Induction time (h):
- 120
- Result:
- positive outcome (effect observed)
- Remarks:
- Exothermic effect at 254 °C
- Remarks on result:
- other: Appearance of the sample after the measurement: Dark gray to black powdery, molten residue
- Test procedure:
- other: Warm storage behavior by means of a wire basket
- Max. temp. reached:
- 209
- Induction time (h):
- 120
- Result:
- negative outcome (no effect observed)
- Remarks on result:
- other: Appearance of the sample after the measurement: Optically almost unchanged
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Solvent Red 52 has no self-heating properties.
- Executive summary:
According to the German standard method "VDI 2263, Sheet 1" Solvent Red 52 has no self-heating properties.
- Endpoint:
- flammable solids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Test procedure:
- burning rate test: preliminary screening test
- Remarks on result:
- substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
- Interpretation of results:
- not classified based on GHS criteria
Referenceopen allclose all
Details on measurement:
Storage temperature (°C) |
Volume (mL) |
Type of gas |
Gas volume (L/h) |
Temperature maximum (°C) |
209 |
400 |
air |
100 |
209 |
219 | 400 |
air |
100 |
254 |
Description of key information
In a test according to EU A.10 the substance did not burn. Solvent Red 52 melted when approached by the flame.
In a supporting study according to EU. A.17 the mixture of 90% Solvent Red 52 with 10 90% Cellulose did not ignite. The flame extinguished already in the start-up-length.
Key value for chemical safety assessment
- Flammability:
- not classified
Additional information
a.) Flammability:
In a test according ot EU A.10 the substance did not burn. The test substance melted when approached by the flame.
In a test according to EU. A.17 the mixture of 90% Solvent Red 52 with 10 -90% Cellulose did not ignite. The flame extinguished already in the start-up-length.
b.) Pyrophoric properties: Solvent Red 52 did not deliver indications of pyrophoric properties during the realization of other tests. The determination according to UN-MTC Procedure N.2 is not necessary.
c.) Contact with water:The chemical structure of the substance contains no metals or metalloids. Testing according to UN-MTC*) procedure N.5 is not necessary with reference to Appendix 6, chapter 5.3..
d.) Self-heating substances: According to the German standard method "VDI 2263, Sheet 1" Solvent Red 52 has no self-heating properties.
Justification for classification or non-classification
Solvent Red 52 is a non-flammable solid, is not flammable in contact with water and does not exhibit pyrophoric or self heating properties.
Bases on the available information Solvent Red 52 is not classified for physical hazards according to Regulation (EC) No 1272/2008 (CLP).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.