Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014-03-20 to 2014-03-27
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point:
178 °C
Atm. press.:
100.4 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 178 ± 2°C.
Executive summary:

Guideline

Method A9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008

Method

Closed cup

Result

The flash point of the test item has been determined to be 178 ± 2 °C.

Description of key information

The flash point of the test item has been determined to be 178 ± 2°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
178 °C

Additional information

The flash point of the test item has been determined to be 178 ± 2°C.