Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
experimental phase from 2014-01-30 to 2014-02-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to OECD/EU guideline, and under GLP. Deviation was not considered significant. Test substance is adequately specified with purity. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Principles of method if other than guideline:
(not applicable)
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected on June 3 to 5, 2013 / signed on November 5, 2013
Type of method:
flask method
Key result
Water solubility:
492 mg/L
Conc. based on:
test mat. (dissolved fraction)
Loading of aqueous phase:
2.2 g/L
Incubation duration:
ca. 24 - ca. 72 h
Temp.:
20 °C
pH:
ca. 4.7
Details on results:
The analytical method was validated and tested with satisfactory results in regard to linearity, accuracy, precision and specificity:
Linearity
System quantification limit = 5 mg/L
Range: 5 – 200 mg/L with r2 = 0.9997 (n=6)
Limit of Quantification = 25 mg/L.
Accuracy
Recovery rates were 102 % for the 1 x LOQ (RSD=1.18%) and 100 % for the 5 x LOQ (RSD=0.32 %).
Specificity
The analyte spectra of the samples matched with standard spectra with sufficient confirmation of identity. Response of blank values of control samples was significantly lower than 30% of LOQ.

Water solubility results

No Tyndall‑effects were observed for any sample during this study.

Sampling interval

Replicate No.

Measured
pH

Water solubility
[mg/L]

Concentration (1)

Mean

24 h

1

4.7

487

486

2

4.7

486

48 h

1

4.7

488

488

2

4.7

487

72 h

1

4.7

500

501

2

4.7

501

Mean (24 - 72 h)

 

4.7

 

492

Maximum deviation [%]

 

2.96

 (1) mean value of triplicate samples each double injected

Conclusions:
Moderately soluble (100-1000 mg/L)
Executive summary:

The water solubility of the test item was determined according to OECD 105 / EC A6 guidelines, under GLP, using the flask method, in double distilled water, at 20°C with preincubation at 30°C .

Equilibrium was considered achieved at first sampling interval (24h).

Analytical evaluation was performed using HPLC-DAD. The analytical method was validated with satisfactory results regarding linearity, limit of quantification, accuracy, precision and specificity.

The water solubility was determined to be 492 mg/L (20 °C, pH 4.7)

Description of key information

Moderately soluble. Equilibrium after 24h.
pH of saturated solution: 4.7

Key value for chemical safety assessment

Water solubility:
492 mg/L
at the temperature of:
20 °C

Additional information

A fully reliable experimental study, conducted according to OECD/EC guidelines (flask method) and under GLP, is available. Therefore, it is considered as a key study, and the result is retained as key data.