Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 281-092-1 | CAS number: 83863-30-3 Extractives and their physically modified derivatives such as tinctures, concretes, absolutes, essential oils, oleoresins, terpenes, terpene-free fractions, distillates, residues, etc., obtained from Cananga odorata, Annonaceae.
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 07 Dec 2017 - 08 Dec 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- Version / remarks:
- 22 July 2010
- GLP compliance:
- yes
- Specific details on test material used for the study:
- Identification: Ylang Ylang I
Appearance: Clear amber liquid (determined by Charles River Den Bosch)
Batch: 17046299
Purity/Composition: UVCB
Test item storage: At room temperature
Stable under storage conditions until: 30 November 2019 (expiry date)
Additional information:
Specific gravity / density: 0.940 (0.933-0.949) - Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- The batch of Ylang Ylang I tested was a clear amber liquid (UVCB). No correction was made for the purity/composition of the test item. The test item was not sufficiently soluble to allow preparation of an aqueous solution at a concentration of 10 g/L. The test item was pipetted directly into the Milli-RO water and stirred briefly to mix. Subsequently, synthetic medium, sludge and Milli-RO water were added resulting in the required concentrations. Optimal contact between the test item and test medium was ensured by applying continuous aeration and stirring during the 3-hour exposure period. Thereafter, oxygen consumption was recorded for approximately 10 minutes.
- Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected: Municipal sewage treatment plant: 'Waterschap Aa en Maas', 's- Hertogenbosch, The Netherlands, receiving predominantly domestic sewage
- Preparation of inoculum for exposure: The sludge was coarsely sieved (1 mm) and allowed to settle. The supernatant was removed and ISO-medium was added. The pH was 7.5 on the day of testing.
- Pretreatment: The batch of sludge was used one day after collection. Therefore, 50 mL of synthetic medium was added per litre of activated sludge at the end of the collection day. The sludge was kept aerated at test temperature until use.
- Initial biomass concentration: A small amount of the sludge was weighed and dried overnight at ca. 105°C to determine the amount of suspended solids, i.e. 3.0 g/L of sludge. The amount of suspended solids in the final test mixture was 1.5 g/L. - Test type:
- not specified
- Water media type:
- other: water Tap water purified by reverse osmosis (Millipore Corp.,Bedford, Mass., USA)
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Remarks on exposure duration:
- Optimal contact between the test item and test medium was ensured by applying continuous aeration and stirring during the 3-hour exposure period.
- Test temperature:
- 20 - 22°C
- pH:
- T 0hr control: 7.6
T 3hr control: 7.6-7.9
T 0hr test item: 7.6
T 3hr test item: 7.6 - 7.8
T 0hr 3,5 DCP: 7.6
T 3hr 3,5 DCP: 7.9-8.1 - Dissolved oxygen:
- >60-70% of air saturation at test start
- Nominal and measured concentrations:
- Test substance
Nominal: 10, 100 and 1000 mg/L - Details on test conditions:
- TEST SYSTEM
- Test vessel: all glass open bottles/vessels
- Total fill volume: 500 mL (250 mL test solution (incl. synthetic medium) + 250 mL activated sludge in test medium)
- Aeration: yes (aeration was adjusted in such a way that the dissolved oxygen concentration at the start was above 60-70% saturation (60% of air saturation is > 5 mg/L at 20°C) and to maintain the sludge flocs in suspension)
- No. of vessels per concentration (replicates): 1 replicate for the lower conentrations and 3 for the highest concentration
- No. of vessels per control (replicates): 6
- No. of vessels per positive control (replicates): 4
- No. of vessels per abiotic control (replicates): 1
- Sludge concentration (weight of dry solids per volume): 1.5 g/L sludge
- Nutrients provided for bacteria: synthetic medium acc. to OECD 209
- Nitrification inhibitor used : no
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: Adjusted ISO-medium, formulated using RO-water (tap water purified by reverse osmosis; GEON Waterbehandeling, Berkel- Enschot, The Netherlands) with the following composition:
CaCl2.2H2O 211.5 mg/L
MgSO4.7H2O 88.8 mg/L
NaHCO3 46.7 mg/L
KCl 4.2 mg/L
OTHER TEST CONDITIONS
- Adjustment of pH: no
- Details on termination of incubation: After the 3-hour contact time, the oxygen consumption was recorded for a period of approximately 10 minutes. During measurement, the sample was not aerated but continuously stirred on a magnetic stirrer.
- Synthetic medium:
16 g peptone (=sewage feed)
11 g meat extract
3 g urea
0.7 g NaCl
0.4 g CaCl2.2H2O
0.2 g MgSO4.7H2O
2.8 g K2HPO4
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : oxygen uptake
TEST CONCENTRATIONS
- Range finding study
- Test concentrations: loading rates of 10, 100 and 1000 mg/L
- Results used to determine the conditions for the definitive study: yes; The combined limit/range-finding test showed no inhibition at 10 and 100 mg/L and an average of 32% inhibition of the respiration rate at 1000 mg/L. Therefore, the EC50 was above the highest concentration tested (1000 mg/L). - Reference substance (positive control):
- yes
- Remarks:
- 3,5-Dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- Inhibition of the Respiration Rate:
The combined limit/range-finding test showed no inhibition at 10 and 100 mg/L and an average of 32% inhibition of the respiration rate at 1000 mg/L. Therefore, the EC50 was above the highest concentration tested (1000 mg/L). In the present test Ylang Ylang I was slightly toxic to waste water (activated sludge) bacteria at 1000 mg/L. Therefore, a NOEC could not be determined. As discussed with the sponsor no further testing was performed to determine the NOEC. There was no oxygen uptake from abiotic processes.
Acceptability of the test:
1. The mean control oxygen uptake rate exceeded 20 mg oxygen per one gram of activated sludge (dry weight of suspended solids) in an hour (24 mg oxygen per one gram of activated sludge).
The coefficient of variation of oxygen uptake in control replicates did not exceed 30% at the end of the definitive test (7%).
2. The EC50 of 3,5-dichlorophenol was in the accepted range of 2 to 25 mg/L for total respiration (7 mg/L). - Results with reference substance (positive control):
- The batch of activated sludge was tested for sensitivity with the reference item 3,5- dichlorophenol, and showed normal sensitivity.
EC50 = 6.94 mg/L ( 95% Cl: 3.36 - 10.62) (falls within the OECD reported range for total respiration, i.e. 2-25 mg/L) - Reported statistics and error estimates:
- Evaluation was based on the inhibition of the total respiration.
ECx and ECx:
For the reference item calculation of the EC50 value was based on a 3-parameter logistic cumulative distribution function (CDF) using non-linear regression analysis, with the percentages of respiration inhibition versus the logarithms of the corresponding concentrations of the reference item.
For Ylang Ylang I, no EC50 value could be calculated because effects were below 50% (EC50 > 1000 mg/L).
NOEC determination:
An effect was considered to be significant if statistical analysis of the data obtained for the test concentrations compared with those obtained in the control revealed significant inhibition of the respiration rate (Two-sample t-test Procedure, α=0.05, one-sided, smaller). Calculations were performed with ToxRat Professional v. 3.2.1. (ToxRat Solutions® GmbH, Germany). - Validity criteria fulfilled:
- yes
- Remarks:
- see details on results
- Conclusions:
- Ylang Ylang I was slightly toxic to waste water bacteria (activated sludge) at 1000 mg/L. The EC50 was above 1000 mg/L.
- Executive summary:
A study was performed to assess the effect of Ylang Ylang I on the respiration of activated sewage sludge according to OECD 209 and GLP guidelines. In a combined limit/range finding test, micro-organisms in activated sludge (in test medium) were exposed to test concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for 3 hours. Optimal contact between the test item and test medium was ensured by applying continuous stirring and aeration during that period. In parallel, an untreated control (6 replicates), reference substance (3,5 -dichlorophenol, 4 replicates) and abiotic control (1 replicate) were tested. After the 3-hour contact time, the oxygen consumption was recorded for a period of approximately 10 minutes (no aeration but continuous stirring).The study met the acceptability criteria prescribed by the study plan and was considered valid. There was no oxygen uptake from abiotic processes and the reference item 3,5- dichlorophenol showed normal sensitivity. In this test, Ylang Ylang I was slightly toxic to waste water (activated sludge) bacteria at 1000 mg/L, as shown by a 32% inhibition of the respiration rate. A NOEC could not be determined. The EC50 was concluded to be above 1000 mg/L.
Reference
Results - Respiration Rate/Inhibition
Replicate |
Concentration (mg/L) |
Respiration rate |
% Inhibition respiration rate (mean value) |
|
(mg O2/L.h) |
(mg O2/g.h)¹ |
|||
C 1 |
0 |
34.99 |
23.33 |
|
C 2 |
0 |
39.57 |
26.38 |
|
C 3 |
0 |
34.17 |
22.78 |
|
C 4 |
0 |
36.75 |
24.50 |
|
C 5 |
0 |
39.16 |
26.11 |
|
C 6 |
0 |
34.09 |
22.73 |
|
C Mean |
|
36.46 |
24.30 (RC) |
|
SD |
|
2.45 |
1.63 |
|
CV (%) |
|
7 |
7 |
|
|
|
|
|
|
R 1 |
1.0 |
36.98 |
24.65 |
-1.44 |
R 2 |
3.2 |
24.50 |
16.33 |
32.79 |
R 3 |
10 |
15.21 |
10.14 |
58.28 |
R 4 |
32 |
7.04 |
4.69 |
80.69 |
|
|
|
|
|
T 1 |
10 |
42.26 |
28.17 |
-15.92 |
T 2 |
100 |
38.59 |
25.73 |
-5.86 |
T 3a |
1000 |
26.81 |
17.87 |
26.46 |
T 3b |
1000 |
21.48 |
14.32 |
41.08 |
T 3c |
1000 |
26.21 |
17.47 |
28.10 |
T3 Mean |
24.83 |
16.56 (RT) * |
31.88 (IT) |
|
|
|
|
|
|
TA |
1000 |
0.00# |
0.00# |
100.00 |
C: |
Control |
R: |
Reference item, 3,5-dichlorophenol |
T: |
Test item, Ylang Ylang I |
TA: |
Abiotic control of Ylang Ylang I |
SD: |
Standard deviation |
CV: |
Coefficient of variation |
* |
Statistically significantly different compared to control |
¹ |
The amount of suspended solids in the final test mixture was 1.5 g/L. |
RC: |
Total respiration in the control |
RT: |
Total respiration with Ylang Ylang I |
IT: |
% inhibition of total respiration relative to RC |
# |
No respiration, therefore expressed as 0 mg O2/L.h |
Description of key information
A study was performed to assess the effect of Ylang Ylang I on the respiration of activated sewage sludge according to OECD 209 and GLP guidelines. In a combined limit/range finding test, micro-organisms in activated sludge (in test medium) were exposed to test concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for 3 hours. Optimal contact between the test item and test medium was ensured by applying continuous stirring and aeration during that period. In parallel, an untreated control (6 replicates), reference substance (3,5 -dichlorophenol, 4 replicates) and abiotic control (1 replicate) were tested. After the 3-hour contact time, the oxygen consumption was recorded for a period of approximately 10 minutes (no aeration but continuous stirring).The study met the acceptability criteria prescribed by the study plan and was considered valid. There was no oxygen uptake from abiotic processes and the reference item 3,5- dichlorophenol showed normal sensitivity. In this test,Ylang Ylang Iwas slightly toxic to waste water (activated sludge) bacteria at 1000 mg/L, as shown by a 32% inhibition of the respiration rate. A NOEC could not be determined.The EC50 was concluded to be above 1000 mg/L.
Key value for chemical safety assessment
- EC50 for microorganisms:
- 1 000 mg/L
Additional information
The EC50 was determined to be above 1000 mg/L.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.