Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 1.028 µm
Remarks on result:
other: No information on standard deviation
Key result
Percentile:
D50
Mean:
ca. 2.525 µm
Remarks on result:
other: No information on standard deviation
Percentile:
D90
Mean:
ca. 5.119 µm
Remarks on result:
other: No information on standard deviation
Conclusions:
test done according to standard protocol, useful to assess the characteristic of the substance
Executive summary:

The particle size of the substance was determined by laser diffraction.

The D50of the substance by volumic distribution is 2.525µm

Description of key information

The D50 of the substance by volumic distribution 2.525µm
    
    
    

The D50of the substance by volumic distribution is 2.525µm

Additional information