Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 September 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Qualifier:
equivalent or similar to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Type:
log Pow
Partition coefficient:
< 0.3
Temp.:
25 °C
pH:
7.5
Details on results:
The partition coefficient of the substance is smaller than that of 2 butanone

log k and log POWof Reference Items

Compound

log k

log POW

2-Butanone

-0.4904

0.30

Benzylalcohol

-0.2474

1.10

Acetophenone

-0.0322

1.70

Nitrobenzene

0.1061

1.90

Benzene

0.3451

2.10

Toluene

0.6005

2.70

Equation of the regression: log k = 0.4619 * log POW– 0.7075 with a coefficient of determination r2= 0.9549

Retention Times, Capacity Factor, log Capacity Factor, log POWTest Item

Measurement

RT min

k

log k

log POW

Measurement 1

0.865

-0.3771

n.c.*

n.c.*

Measurement 2

0.868

-0.3751

n.c.*

n.c.*

Measurement 3

0.867

-0.3754

n.c.*

n.c.*

Mean

0.867

 

 

n.c.*

Standard deviation

0.002

 

 

n.c.*

* Not calculable, because k is negative. The retention time of the peak is lower than the retention time of thiourea (1.389 min), which was used for the determination of the dead time of the method

Conclusions:
The logPow of the substance is < 0.3
Executive summary:

In a test using the HPLC method the retention time of the substance lay below of the retention time of thiourea. Therefore the log Pow is stated as < 0.3.

Description of key information

In a test using the HPLC method the retention time of the substance lay below of the retention time of thiourea. Therefore the log Powis stated as < 0.3.

Key value for chemical safety assessment

Log Kow (Log Pow):
0.3
at the temperature of:
25 °C

Additional information