Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23.10.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Other quality assurance:
other:
Type of method:
open cup
Flash point apparatus:
other:
Key result
Flash point:
ca. 157 °C
Atm. press.:
ca. 101 325 Pa
Interpretation of results:
GHS criteria not met

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
157 °C

Additional information

Standard deviation: 2.0 °C