Administrative data

First-aid measures

General advice:
Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled:
If breathed in, move person into fresh air. If not breathing, give artificial respiration.
Consult a physician.

In case of skin contact:
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician.

In case of eye contact:
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed:
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse
mouth with water. Consult a physician.

Fire-fighting measures

Suitable extinguishing media: Dry powder Dry sand

Unsuitable extinguishing media: Do NOT use water jet.

Special hazards arising from the substance or mixture: Carbon oxides

Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.

Further information: Use water spray to cool unopened containers.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.

Environmental precautions:
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Discharge into the environment must be avoided.

Methods and materials for containment and cleaning up:
Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).

Handling and storage

Precautions for safe handling:
Avoid inhalation of vapour or mist.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.

Conditions for safe storage, including any incompatibilities:
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store in cool place. Heat-, light-, and moisture-sensitive. Dry residue is explosive.
Storage class (TRGS 510): 3: Flammable liquids

Specific end use(s):
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 1088
Shipping information
Proper shipping name and description:
ACETAL
Chemical name:
Acetaldehyde diethyl acetal
Language:
English
Special provisions / remarks
Special provisions:
Tunnel restriction code: D/E
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN1088
Shipping information
Proper shipping name and description:
ACETAL
Chemical name:
Acetaldehyde diethyl acetal
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN1088
Shipping information
Proper shipping name and description:
ACETAL
Chemical name:
Acetaldehyde diethyl acetal
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:
Components with workplace control parameters
Contains no substances with occupational exposure limit values.

Exposure controls - Appropriate engineering controls:
Handle in accordance with good industrial hygiene and safety practice. Wash hands
before breaks and at the end of workday.

Personal protective equipment:

Eye/face protection:
Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection:
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact
with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

Full contact:
Material: butyl-rubber
Minimum layer thickness: 0,3 mm
Break through time: 480 min
Material tested:Butoject® (KCL 897 / Aldrich Z677647, Size M)

Splash contact:
Material: Nitrile rubber
Minimum layer thickness: 0,4 mm
Break through time: 30 min
Material tested:Camatril® (KCL 730 / Aldrich Z677442, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail
sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This
recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Body Protection:
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the
concentration and amount of the dangerous substance at the specific workplace.

Respiratory protection:
Where risk assessment shows air-purifying respirators are appropriate use a fullface respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Control of environmental exposure:
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Discharge into the environment must be avoided.

Stability and reactivity

Reactivity: No data available.

Chemical stability: Stable under recommended storage conditions.

Possibility of hazardous reactions: No data available.

Conditions to avoid: Heat, flames and sparks.

Incompatible materials: Strong oxidizing agents, Strong reducing agents, Strong bases

Hazardous decomposition products: Hazardous decomposition products formed under fire conditions. - Carbon oxides
Other decomposition products - No data available

Disposal considerations

Waste treatment methods:

Product: Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.

Contaminated packaging: Dispose of as unused product.